DAVIS TMS-5500-SL Manual

DAVIS TMS-5500-SL Manual

Electronic points electronic traction control

Advertisement

Quick Links

WWW.MORETRACTION.COM
TMS-5500-SL
Electronic Points
ELECTRONIC
TRACTION CONTROL
US PATENT 6,577,944
Other Patents Pending

Advertisement

Table of Contents
loading

Summary of Contents for DAVIS TMS-5500-SL

  • Page 1 WWW.MORETRACTION.COM TMS-5500-SL Electronic Points ELECTRONIC TRACTION CONTROL US PATENT 6,577,944 Other Patents Pending...
  • Page 2 COPYRIGHT NOTICE Copyright © 1999-2014 Davis Technologies, LLC. All rights reserved. Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders. Any components shown are for illustration or instructional purposes only.
  • Page 3: Table Of Contents

    Table of Contents Table of Contents ............1 Introduction ..............3 How Does It Work? ............4 Installation ..............6 Make Connections as follows: ......... 7 Testing ................9 Forced Activation Test: ..........9 RPM Window Test: ............. 10 Traction Control Adjustments ......... 11 Traction Control Setup ..........
  • Page 4 Advanced Main Tab Settings: ........34 More Tab Settings: ........... 35 More Tab Advanced Settings: ......... 37 Admin Tab: ..............39 USB to Serial Adapter: ........... 40 Handheld Programmer ..........42 DISCLAIMER ..............43 Notes ................44 Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 5: Introduction

    Testing is very important since it will help you utilize this product to its full potential. Please read all of the instructions and information thoroughly before attempting to install or use this product. Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 6: How Does It Work

    20-25% to fix it. But if the tire slip is detected within one cylinder worth of crank rotation, as the Davis Technologies systems do, then a small reduction in power can reduce or stop the tire slip.
  • Page 7 In fact, Davis Technologies’ systems are at least 20 times faster than other systems which are integrated into the fuel injection or ignition system.
  • Page 8: Installation

    ® Super Conductor® wires are recommended. Resistor type racing plugs may also be used if supression wires are not available. Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 9: Make Connections As Follows

    “GND” terminal and the magneto body will cause failure! 4. Connect the terminal marked “KILL” to the NEG Coil Terminal. WARNING-HIGH VOLTAGE !! Failure to properly handle and insulate connection could result in electrical shock! Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 10 If a problem is suspected then the unit can simply be disconnected from the kill wire leaving the engine in original form. Disconnecting the power supply should also deactivate the system. Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 11: Testing

    The first timing retard stage will activate for 4 seconds, then the second stage for the next 4 seconds. Note: After the test is complete, the LED will blink to show the firmware version. Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 12: Rpm Window Test

    ® Super Conductor® wires are recommended. Resistor type racing plugs may also be used if supression wires are not available. Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 13: Traction Control Adjustments

    Traction Control Adjustments Davis Technologies’ patented systems have the ability to learn the amount of acceleration that the vehicle is achieving on average and activate the outputs if this learned average is exceeded. Different tracks, cars, conditions, etc. require different settings for the system to function effectively.
  • Page 14 (When using this method the Mode setting has no effect on the system, with the exception of Mode 0, or Mode 9). (M0 turns unit off, except for sensor test / M9 activates window RPM test). Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 15: Traction Control Setup

    This may allow for easier starting, but may not be compatible with all magnetos. The retard can be adjusted from 10-18 degrees in 2 degree increments, or turned off. Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 16: Buffer

    This is useful to force the timing to stay retarded long enough to stop a high momentum spin, even though the RPM spike was very brief. (This setting only accessible using the “Traction Control Panel Software” or a Handheld Programmer) Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 17: Small Corrections Only Rpm

    Once set the value will remain until changed by the user. The RPM is set in a % of the maximum RPM turned at the end of the strait. (Default=85-95%) Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 18: Configuring

    (example- 4 triggers/2=2) Release the “Test” button. The LED will flash to show the number of triggers the unit is now set to. (The Trigger Count must be set correctly for the accurate RPM calculations) Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 19: Starting Rpm

    Starting RPM is set to. The first digit is output followed by a short pause, then the second digit is output. (5000 RPM = 5,0 Blinks) (zeros are indicated by shorter blinks) Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 20: Rev Limiter

    Note: The Rev Limiter can be tested at ½ of the set value by setting the “T” dial to “0” and holding down the Test button. (9000 RPM Rev Limit will cut engine at 4500 during test) Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 21: Start Retard

    To change the value, follow these steps. Set the “M” dial to “1” Hold down the “Test” button Turn the power On While holding the “Test” button down, move the dial to the desired buffer value. Release the “Test” button, Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 22: Sample Rate

    Sample Rate value. Release the “Test” button, The LED will flash to show the value that the Sample Rate is now set to. Valid settings are 1-5. (Most users never need to adjust the Sample Rate) Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 23: Small Corrections Only Rpm

    Ending RPM is set to. The first digit is output followed by a short pause, then the second digit is output. (75% = 7,5 Blinks) (zeros are indicated by shorter blinks) Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 24: Ending Rpm

    Ending RPM is set to. The first digit is output followed by a short pause, then the second digit is output. (95% = 9,5 Blinks) (zeros are indicated by shorter blinks) Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 25: Confirming Settings

    After a short pause, the Led will flash for the value of Sample Rate, followed by a pause. Lastly, the LED will Flash the current Self Learning status value. (for tech support purposes only). Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 26: Advanced

    After a short pause, the LED will flash for the value of Minimum Corrections. (Default = 9) After a short pause, the LED will flash for the value of Type. (1 = Asphalt, 2 = Dirt) Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 27: Rpm

    After a pause, the value for the END RPM% is shown. The LED will blink for the first digit followed by a short pause, then the LED will blink for the second digit.(95%= 9,5 Blinks) (zeros are indicated by shorter blinks). Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 28: Mag

    9,7 Blinks) (zeros are indicated by shorter blinks). After a short pause, the LED will flash for the value of Retard -“T“ (this is only shown if Handheld programmer is used to remotely configure unit). Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 29: Factory Reset

    Turn the power On While holding the “Test” button down, move the dial to the “Off“ position. Release the “Test” button, The LED will flash rapidly to indicate the Factory Settings have been restored. Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 30: Firmware Updating

    Traction Control System. The traction control unit will need to be returned to Davis Technologies to have the updates installed and configured. Users should log onto www.moretraction.com, or call...
  • Page 31 A system that uses a preset percentage of slip, between the rear wheel speed to front wheel (or ground) speed, cannot compensate for these changing conditions that are inherent in all types of racing. Traction Control Is What We Do! Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 32 This Page Left Blank Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 33: Traction Control Panel Software

    The Traction Control is connected to the computer via a serial cable or through a secure wireless Bluetooth connection. Tuning is achieved through a few simple mouse clicks. Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 34: Main Tab Settings

    “Set Dials Here” box. When checked, the TC unit only uses the TCP settings, and the setting cannot be changed using the button on the unit. To use the button method, YOU MUST UN-CHECK THIS BOX! Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 35 Main Tab- Basic Screen Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 36: Advanced Main Tab Settings

    The higher the number the slower the Sample Rate, which makes the unit more sensitive, but slower to react. Valid settings are 1-5. (Default=5) Main Tab- Advanced Screen Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 37: More Tab Settings

    More Tab Settings: Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 38 TC is picking up for each revolution of the measured shaft. In most cases, this is the number of cylinders, divided by 2. For a V8, set the Triggers to 4. More Tab- Basic Screen Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 39: More Tab Advanced Settings

    More Tab Advanced Settings: Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 40 RPM actually reached on the track. Min Corrections: sets the minimum number of cylinders, in full revolutions, that will be retarded if a correction is made by the traction control unit. More Tab- Advanced Screen Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 41: Admin Tab

    Admin Tab: Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 42: Usb To Serial Adapter

    The Admin screen is used to provide information about the unit for tech support by Davis Technologies. USB to Serial Adapter: Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 43 Davis Technologies offers a model that has been tested on may brands of computers as well as across many operating systems. These are available for $29.95 from Davis Technologies directly. Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 44: Handheld Programmer

    TCP software does, but is a simple, self contained system that does not require a computer. Most users prefer the handheld. The handheld programmer is available as a hard wired unit, or a wireless Bluetooth connected unit. Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 45: Disclaimer

    The Davis Technologies, LLC’s products and parts warranties are voided if the vehicle or part is used for competition or if they fail as a result of modification.
  • Page 46: Notes

    Notes Davis Technologies TMS-5500-SL Elec Points www.moretraction.com...
  • Page 47 Contact Information Technical support and sales may be reached at: Davis Technologies, llc. PO Box 8250 Asheville, NC. 28787 (828) 645-1505 (828) 645-1525 fax email: support@moretraction.com web: www.MORETRACTION.com...

Table of Contents