Intermatic RC613 Installation, Operation & Service Manual

Intermatic RC613 Installation, Operation & Service Manual

Rc series remote controls single channel radio receivers

Advertisement

Quick Links

RC SERIES
REMOTE CONTROLS
SINGLE CHANNEL RADIO RECEIVERS
Model: RC613, RC613L Switching Module / Model: RC615 Timer Override Module
For indoor and outdoor use, suitable for Pool/Spa equipment control
ELECTRICAL RATING: 15 Amp Resistive, 1200 Watt Tungsten, 1 HP Motor Load - 120 Volt.
THIS DEVICE COMPLIES WITH FCC RULES PART 15. Operation of this device is subject to the following two conditions
1. This device may not cause harmful interference. 2. This device must accept any interference that may be received,
including interference that may cause undesired operation. FCC rules prohibit adjustments to or modification of receiver and
transmitter circuitry except for replacing the remote control battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
1. This Control must be installed by a qualified electrician, according to National and Local Electrical Codes.
2. USE COPPER CONDUCTORS ONLY. If applicable, install this Control not less than 5 feet (3 meters for Canadian
installations) of inside edge of pool or spa.
3. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors.
4. For grounding of the installation, refer to section 250 and 680 of the National Electrical Code.
5. This Control should not operate any equipment which would cause bodily injury or property damage should it be
activated unexpectedly.
6. Always disconnect electricity at main panel before servicing this Control or the equipment(s) connected to it.
THIS CONTROL IS NOT TO BE USED AS A POWER DISCONNECT.
These Modular Radio Receivers are one half of a two part remote control system.
They operate as ordinary ON/OFF switches but they also respond to the signals of
a hand held transmitter - the other half of the system. The modules are designed for
indoor or outdoor use, and can handle a variety of switching applications, typical
around the house or farm. By the push of a button on the face of the transmitter, the
user is able to turn ON/OFF the connected load (lights, pump, etc.) from any remote
location*, safely and conveniently. In addition, a single transmitter can operate up to
four Receivers and is able to "teach" each Module a different code. (Transmitters are
sold separately).
Model RC613 Receiver Module comes with its own manual ON/OFF button and
it is intended to be installed at the location of the load. The connected load may be
turned ON/OFF using the hand-held transmitter or turned ON/OFF by pushing the red
button on the face of the Receiver.
Model RC613L Receiver Module is the same as RC613 except that it comes with
extra long (36 in.) leads.
Model RC615 Receiver Module is the same as the RC613L Module above, except
it has no manual ON/OFF button on its face. This Module is designed to be con-
nected to a timer and will override its pre-set program, without affecting the next
automatic operation. At-site control of the load is possible by the ON/OFF switch of
the timer.
* The open field range is 200 feet but depends on many factors like the age of the battery, proximity of
large metal objects, the location of the receiver and environmental conditions at the time of transmission.

IMPORTANT SAFETY INSTRUCTIONS

READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL

GENERAL INFORMATION

SERVICE MANUAL
1
INSTALLATION
OPERATION &

Advertisement

loading

Summary of Contents for Intermatic RC613

  • Page 1: Important Safety Instructions

    ON/OFF using the hand-held transmitter or turned ON/OFF by pushing the red button on the face of the Receiver. Model RC613L Receiver Module is the same as RC613 except that it comes with extra long (36 in.) leads. Model RC615 Receiver Module is the same as the RC613L Module above, except it has no manual ON/OFF button on its face.
  • Page 2: Useful Information

    Make sure the intended load is within the capacity of the Module, see ratings on page 1 and other choices on page 4. 1. Attach RC613 Receiver Module to the top of an outdoor grade junction box. Make sure the assembly is raintight.
  • Page 3 Receiver Module. Otherwise, the timer mechanism must be replaced with Intermatic Model PT1203M, see also other choices on page 4. 1. Select the proper location (see Useful Information on page 2) and install a radio...
  • Page 4: Troubleshooting

    Faulty receiver ....... . .Replace receiver module If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, the unit free of charge.

This manual is also suitable for:

Rc613lRc615