Gallagher W- Weigh Scale User Guide
In either mode, you can re-weigh an animal by pressing
successful weight lock.
By default the scale will automa cally zero any debris le on the pla orm
between 2-5kg depending on the capacity of your loadbars. This can be
altered in the connected loadbar se ngs.
Session Options
The Sessions Op ons menu is used to confi gure se ngs for the current session.
1.
From this screen you can change the session name, turn dra ing On or Off ,
change the weight lock mode and confi gure Advanced se ngs.
Save
2.
Select
Drafting
Animals can be drafted into groups based on their weight, current weight gain,
overall weight gain or drafted by a pre-defined list of animals IDs.
From the Sessions Op ons menu, select a dra op on.
1. To dra by: Weight, Current Weight Gain, Overall Weight Gain
Enter the number of draft groups in the session and select
Change the assigned weight ranges, group names or gate numbers.
Select
2. To draft by list (Animal ID)
Enter the number of draft groups in the session and select
Draft lists previously uploaded to the scale are displayed. Select the
appropriate draft list.
Note: The draft list is created on the Animal Performance Software and
synchronised to the scale. Refer to Transfer Session Data (p. 11).
Save
During the session, the gate number and group will display, in the top right corner
of the weigh screen. To override the dra ing decision, navigate to the Dra Group
box and press OK to change the decision. Manually open the nominated gate.
.
Done
Save
and
the Session options.
the Session options.
Weigh
a er a
Next
.
Next
.