The self-evaporating system uses the collected water to cool the condenser coils for better efficient
performance. It is no need to empty the drainage tank in cooling operation except in drying
operation and high humidity conditions. The condensate water evaporates at the condenser and
evacuated through the exhaust hose.
For continuous operation or unattended operating in drying operation, please connect the attached
drain hose to the unit. Condensate water can be automatically flow into a bucket or drain by gravity.
Switch off the unit before operating.
Remove the plug of the water outlet opening, and
keep it in safe area.
Securely and properly connect the drain hose and
make sure it is not kinked and clear of
obstruction.
Place the outlet of hose over a drain or bucket
and ensure that water could freely flow out of the
unit.
Do not submerge the end of hose into water;
otherwise it can cause "Air Lock" in the hose.
To avoid water spillage:
As the negative pressure of condensate drain pan is large, tilt the drain hose downward
toward the floor. It is appropriate that the degree of inclination should exceed 20
degrees.
Straighten the hose to avoid a trap existing in the hose.

CLEANING AND CARE

6.1.
CLEANING THE AIR FILTER (every two weeks)
Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of the
system and if it becomes blocked it can cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate
the unit without an air filter, or the evaporator may be contaminated.
Press POWER button to switch off the unit and unplug the power cord.
5.
Remove the filter mesh from the unit.
6.
Use a vacuum cleaner to suck dust from the filter.
7.
Turn the filter over and rinse the air filter under running water. Let the water run through the filter in
the opposite direction of air flow. Set aside and allow the filter to air dry completely before reinstalling.