Page 1
BWB BriteCor AC Direct Wet Location Brik Installation Manual...
Page 2
Never use a fixture in a two-wire system that is not grounded. • If dimming functionality is included, use only with Litesheet approved dimmers. • This unit is not approved for use in ducted ceilings. • Do not use excessive force when manipulating cables and wires.
Page 3
LiteSheet Solutions CONTENTS OF KIT • BWB Wet Brik • (Optional) Mounting Brackets TOOLS AND ADDITIONAL PARTS REQUIRED • P2 Philips Head Screwdriver / Drill • Flat Head Screwdriver • 3/8” Drive Preparation 1. Turn off power source. Drill and attach mounting screws to mounting surface.
Page 4
BWB BriteCor Wet Brik Installation Manual 2. Lock the bracket in place using the #8-32 side screw. Installation (Adjustable Bracket) 1. Mount the luminaire to the mounting surface using the attached brackets. 2. Adjust the angle of the luminaire to the desired position.
Page 5
LiteSheet Solutions Wiring Guide 1. Temporarily remove the (3) screws from the front of the luminaire. Loosen the 3 screws in the back luminaire. 2. Remove the PG 13.5 end cap from the fixture. Insert incoming power wires/ cable. Reseal the wire port with IP66 or Wet Location rated hardware (not included.)
Page 6
BWB BriteCor Wet Brik Installation Manual 3. Connect the incoming ground connection to the green ground wire provided. Connect the incoming line power to the luminaire disconnect provided. • Black – Line Power (Hot) • White – Neutral • Green – Safety Ground 4.
Page 7
LiteSheet Solutions For warranty information and technical support, contact us at: 434-446-1460 Find more great products at: www.litesheet.com Page 7 of 7...