Innovative BV20 Operation Manual

Innovative bv20 bank note validator: user guide
Hide thumbs Also See for BV20:

Advertisement

Quick Links

BV20
OPERATIONS
MANUAL
INTELLIGENCE IN VALIDAT
Copyright Innovative Technology Ltd 2008
GA794-2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BV20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Innovative BV20

  • Page 1 BV20 OPERATIONS MANUAL INTELLIGENCE IN VALIDAT Copyright Innovative Technology Ltd 2008 GA794-2...
  • Page 2: Table Of Contents

    Serial input/output - SIO Smiley Secure Protocol (SSP) ® Multi-drop bus/internal communications protocol (MDB/ICP) ccTalk protocol - CCT Other interfaces available Using BV20 configuration cards Mechanical installation Routine maintenance Re-calibration Support tools Configuration cards ITL bank note validator currency manager...
  • Page 3: Bv20 Operations Manual

    CAUTIONS · This product must be fitted with a 2 A (ampere) fuse before use. · The BV20 validator is pin for pin compatible with NV7/8/9/10, but not pin for pin compatible with the NV2/3/4/4x or 5 series products. · Due to different note cycle times there may be timing differences from the NV products.
  • Page 4 BV20 Operations Manual GROUP EMAIL CONTACT BRAZIL suporte@bellis-technology.com.br CHINA support@innovative-technology.co.uk COLUMBIA support@automated-transactions.net GERMANY support@automated-transactions.de ENGLAND support@innovative-technology.co.uk SPAIN soporte@automated-transactions.es UNITED STATES OF AMERICA supportusa@bellis-technology.com REST OF THE WORLD sales@innovative-technology.co.uk Copyright Innovative Technology Ltd 2008 GA794-2...
  • Page 5: Environment And Power Requirements

    Humidity Table 1 – Environmental Requirements CAUTIONS: • IF THE INPUT VOLTAGE FALLS BELOW 11.5V THE BV20 MAY NOT OPERATE CORRECTLY (WILL REJECT NOTES). THE FRONT BEZEL LIGHTS WILL FLASH TO INDICATE INCORRECT CONDITIONS • IT IS RECOMMENDED THAT THE POWER SUPPLY USED CAN SUPPLY AT LEAST 1.7 AMPS...
  • Page 6: General Description

    The BV20 is designed for easy installation in most machines. Interfacing the validator is very simple, with the choice...
  • Page 7: Machine Interfaces

    4 MACHINE INTERFACES: HARDWARE The BV20 interface connector is located on the left side of the unit; it has 16 pins (see figure 2) refer to Table 5 for the pin allocation. Two are used for the 0V and +12V power supply and there are five outputs and five inputs, the remaining four pins are reserved for factory use and should not be connected.
  • Page 8 Inhibit channel 3 by holding this pin HIGH Inhibit channel 4 by holding this pin HIGH BV20 is validating and stacking output. Active low while the BV20 is reading, transporting or stacking a note. Operate Escrow function by holding LOW (see Appendix B –...
  • Page 9: Bezel Led's

    (See Program Check Procedure, in Appendix D) Encryption Key Reset Function (ccTalk) Note: This function will only be possible if the BV20 is programmed to ccTalk mode. It is not possible to reset the key from SSP mode.
  • Page 10: Additional Hardware Modules

    The 110V Voltage Regulator Module allows the BV20 to be used with machines that operate with a 110V AC supply. The modules attach to the back of the BV20 and are held in place by the expansion port clips and a single fixing screw. For unit and cable dimensions please see diagrams below.
  • Page 11 BV20 MECHANICAL INSTALLATION Drawing Number GA791 In line with continued product development Innovative Technology Ltd reserves the right to change specifications without prior notice. ACCEPTS NOTES: 1. 66 mm x 160 mm LONG 2. 72 mm x 160 mm LONG...
  • Page 12 BV20 MDB PSU CABLE ASSEMBLY WITH EXTENDED LENGTH AND Y - SPLIT END (MDB PSU TO HOST MACHINE) DRAWING NUMBER CN307 Copyright Innovative Technology Ltd 2008 GA794-2...
  • Page 13 BV20 110V PSU TO HOST MACHINE CABLE ASSEMBLY DRAWING NUMBER CN311 Copyright Innovative Technology Ltd 2008 GA794-2...
  • Page 14: Machine Interface: Protocols

    Configuration Cards (See Appendix D – Configuration Cards) or via the ITL BNV Currency Manager program. In parallel mode the BV20 will issue a 100ms (±3%) active LOW pulse on the relevant vend line. A maximum of 4 channels can be used.
  • Page 15: Pulse Stream Output

    All four inhibits may be connected together to create a 'global' inhibit. In this way the BV20 may be brought in and out of operation by the host machine. Busy Output: (Pin 9). This is a general-purpose busy signal. It is active low while the BV20 is in operation.
  • Page 16 Note: Channels higher than four cannot be individually inhibited, but will be globally inhibited if inhibits 1 to 4 are inhibited. It is possible to operate the BV20 in low power mode with the Pulse interface. For further details please see Chapter 5.4...
  • Page 17: Binary Output - Bin

    Configuration Cards (See Appendix D – Configuration Cards) or via the ITL BNV Currency Manager program. In Binary mode, the BV20 will issue a binary pattern on vend lines 1 to 4 as shown in Table 9 – Binary Credit Outputs. A maximum of 15 channels can be used.
  • Page 18 Low Power Mode can be used with all none serial communication protocols to reduce the power consumption of the BV20 when idle. When the BV20 is in this state the current consumption is reduced to approximately 1.2mA. The BV20 goes into low power mode approximately 4 seconds after the validator is powered up and remains in this state until a note is entered (Time A).
  • Page 19 (Time A) When a note is inserted under the front sensor the BV20 wakes up and the busy line goes low to indicate that the validator is in use. The busy line remains low during the validating and stacking process and once the note has been successfully validated and stacked the vend line goes low to issue the credit.
  • Page 20: Serial Input/Output - Sio

    NV4 to NV10. It is not recommended for use on new designs due to the possibility of noise effecting the communication. We recommend the use of a serial protocol with error checking such as SSP. The BV20 does not support the Simple Serial Data Out Only mode as available on the NV4 and earlier models.
  • Page 21 BV20 Operations Manual The BV20 will receive and transmit the following event codes Recognised Receive Codes to BV20 MESSAGE Inhibit C1 Inhibit C2 Inhibit C3 Inhibit C4 Inhibit C5 Inhibit C6 Inhibit C7 Inhibit C8 Inhibit C9 Inhibit C10 Inhibit C11...
  • Page 22 Status Report 3 byte status message Turn on Escrow Mode Note accept in Escrow Mode Note entered into validator Note Accepted Channel 2 Copyright Innovative Technology Ltd 2008 Validator Decimal Validator Busy Validator Ready Accept on channel 2 Validator Busy...
  • Page 23: Smiley ® Secure Protocol (Ssp)

    Default SSP address: - 0x00 For detailed information and full protocol specification please refer to SSP Interface Specification ITL (Drawing GA 138), this is available from the ITL website www.innovative- technology.co.uk. To help in the software implementation of the SSP, ITL can provide DLL controls and visual basic applications on request.
  • Page 24: Multi-Drop Bus/Internal Communications Protocol (Mdb/Icp)

    BV20 Operations Manual 5.7 MULTI-DROP BUS/INTERNAL COMMUNICATIONS PROTOCOL (MDB/ICP) To use the MDB mode an MDB Voltage Regulator Module should be fitted to the BV20 Expansion Port or alternatively an IF5 Interface Box can be used. The MDB Interface must be programmed into the validator via the Configuration Cards (See Appendix D –...
  • Page 25 BV20 Operations Manual The BV20 Bank Note Validators have a unique address – 00110XXX binary (30H). The VMC polls the bus to detect presence of the BV20 Validator or get information on the current status of the validator. The validators will respond when asked for activity with an acknowledgment, a negative acknowledgment or a specific reply, depending on its current status.
  • Page 26: Cctalk Protocol - Cct

    BV20 Operations Manual 5.8 CCTALK PROTOCOL – CCT The BV20 supports the ccTalk serial protocol for easy interfacing with host machines that support this protocol. To use ccTalk mode The CCT interface must be programmed into the validator via the Configuration Cards (See Appendix D – Configuration Cards) or via the ITL BNV Currency Manager Program.
  • Page 27: Using Bv20 Configuration Cards

    If a configuration card is not entered, this function can be cancelled by pressing the button again once. It is now possible to check the programmed settings of the BV20 by pressing the Configuration button twice within half a second. (For details see page 2 of Appendix D –...
  • Page 28 BV20 OUTLINE DIMENSIONS DRAWING NUMBER GA790 In line with continued product development Innovative Technology Ltd reserves the right to change specifications without prior notice. ACCEPTS NOTES: 1. 66 mm x 160 mm LONG 2. 72 mm x 160 mm LONG SUPPLY AND POWER CONSUMPTION: VOLTAGE: 12 ±...
  • Page 29: Routine Maintenance

    The BV20 Validator has been designed to minimise any performance variation over time. Much of this is achieved by careful Hardware and Software design. However, depending upon the environment in which it is used the BV20 may at some time require re-calibration.
  • Page 30: Itl Bank Note Validator Currency Manager

    • Datasets can only be downloaded to a BV20 with the correct bezel width for the currency. For example a USD dataset can only be downloaded to a 66mm BV20. A Euro dataset can only be downloaded to a 72mm BV20.
  • Page 31: Validator Programming System (Da3)

    9.4 INTERNET WEBSITE SUPPORT The Innovative Technology Ltd website provides the means to download new and updated currency sets and new versions of firmware for the BV20. You can obtain these along with technical bulletins by visiting 9.5 E-MAIL SUPPORT If the data you require is not available over the Internet Innovative Technology supports an e-mail system to help customers with unusual requirements.
  • Page 32: Appendix A - Exploded Diagrams

    PA771 PM774 SC113 PB243 PM773 PA774 PA773 PA781 Transfer Shaft Assembly (PM533, PM772, MC253) LB155 Copyright Innovative Technology Ltd 2008 Part description BV20 Case Bezel 72mm Bezel 66mm 66mm Lens Assembly 72mm Lens Assembly Light Pipe Pressure Wheel Axle Spring Front Axle Assembly Idle gear (16T –...
  • Page 33 BV20 EXPLODED ASSEMBLY DRAWING NUMBER GA792 Copyright Innovative Technology Ltd 2008 GA794-2...
  • Page 34: Appendix B - Escrow Control

    In the event of a note being forcibly removed from the mouth of the BV20 during the 30- second interval, the BV20 will go out of service for 45 seconds.
  • Page 35: Appendix C - Interface Tools Da1 - Da2

    NOTE: The Validator must be in Programming Mode when connected to a computer and then returned to the Original Settings when the download is complete. Figure 8 – Connecting DA1 to BV20 and PC for upgrading Validator programs Copyright Innovative Technology Ltd 2008...
  • Page 36 BV20 Operations Manual Connecting a DA2 to a validator and PC Figure 9 – Connecting a DA2 to a BV20 and PC for upgrading Validator Programs Software Installation DA1 - To install the ITL BNV Download Manager Software insert the CDROM into the correct PC drive.
  • Page 37: Appendix D - Configuration Cards

    NV200 Operations Manual BV20 Operations Manual APPENDIX D – CONFIGURATION CARDS IMPORTANT CHECK THAT THE CONFIGURATION REQUESTED HAS BEEN SET IN THE BV20 BEFORE Copyright Innovative Technology Instructions for use 1) Select correct width card for bezel. Cut card around outline – check measurements as printed.
  • Page 38 BV20 Operations Manual Program check procedure To check settings on a programmed unit: Power on unit Click program set button on unit twice (like double click on mouse) Monitor bezel led and check flash codes For example A Pulse interface with 50ms high, 100ms low, 2 pulse per dollar will flash 2,5,10,2...
  • Page 39 Copyright Innovative Technology GA794-2...
  • Page 40 Copyright Innovative Technology GA794-2...
  • Page 41 Copyright Innovative Technology GA794-2...
  • Page 42 Copyright Innovative Technology GA794-2...
  • Page 43 Below are some typical examples of completed Configuration Cards. Note: These Configuration Cards are samples and should not be copied for programming use. Please see document GA713 for useable cards Parallel Binary Copyright Innovative Technology GA794-2...
  • Page 44 Note: These Configuration Cards are samples and should not be copied for programming use. Please see document GA713 for useable cards. Unencrypted ccTalk Pulse – Pulse width Encrypted ccTalk 50/100 ms 4 Pulses per with 16-bit Checksum Dollar Copyright Innovative Technology GA794-2...
  • Page 45 Note: These Configuration Cards are samples and should not be copied for programming use. Please see document GA713 for useable cards. SIO 300-Baud SIO 9600-Baud SIO 300-Baud SIO 9600-Baud Starts Disabled Starts Disabled Copyright Innovative Technology GA794-2...
  • Page 46: Appendix E - Pc System Specification

    BV20 Operations Manual APPENDIX E - PC System Specification The ITL Validator Software has been tested and verified using Windows 2000 / XP / Vista on a Pentium based PC System ( Microsoft and Intel). © Full functionality cannot be guaranteed on lower specification systems.
  • Page 47: Appendix F - Implemented Cctalk Commands

    BV20 Operations Manual APPENDIX F - IMPLEMENTED CCTALK COMMANDS SIMPLE_POLL ADDRESS_POLL ADDRESS_CLASH ADDRESS_CHANGE ADDRESS_RANDOM REQUEST_POLLING_PRIORITY REQUEST_MANF_ID REQUEST_EQUIP_CAT_ID REQUEST_PRODUCT_CODE SERIAL_NUMBER REQUEST_SOFTWARE_REVISION READ_OPTO_STATES PERFORM_SELF_CHECK SET_INHIBITS REQ_INHIBITS SET_MASTER_INHIBIT REQ_MASTER_INHIBIT REQUEST_INS_COUNT REQUEST_ACCEPT_COUNT REQUEST_DATA_STORAGE_AVAIL REQUEST_OPTION_FLAGS CALCULATE_ROM_CHECKSUM REQUEST_BUILD_CODE REQUEST_BASE_YEAR REQUEST_ADDRESS_MODE READ_BUFFERED_BILL_EV REQUEST_BILL_ID REQUEST_COUNTRY_SCALING REQUEST_BILL_POSITION MODIFY_BILL_OPERATING_MODE REQUEST_BILL_OPERATING_MODE...
  • Page 48 BV20 Operations Manual REVISION HISTORY INNNOVATIVE TECHNOLOGY LTD TITLE BV20 OPERATIONS MANUAL DRAWING NO AUTHOR GA716 ISSUE RELEASE DATE 15/10/00 20/01/00 Copyright Innovative Technology DATE FORMAT 29/07/07 MS Word 2000 MODIFIED BY COMMENTS First Issue Improved Interface descriptions GA794-2...

Table of Contents