Low power option Re-calibration Diagnostics Support Appendix Appendix A – How to order a BV100 Validator Appendix B – Mechanical Installation Appendix C – BV100 Cash boxes Appendix D – Configuration Cards Appendix E – Escrow control Appendix F – Interface tools DA1 – DA2 Appendix G –...
CAUTIONS · This product must be fitted with a 3 A (ampere) fuse before use. · The BV100 validator is pin for pin compatible with NV7/8/9/10, but not pin for pin compatible with the NV2/3/4/4x or 5 series products. · Due to different note cycle times there may be timing differences from the NV products.
Page 4
BV100 Operations Manual GROUP EMAIL CONTACTS BRAZIL suporte@bellis-technology.com.br CHINA support@innovative-technology.co.uk COLUMBIA support@automated-transactions.net GERMANY support@automated-transactions.de ENGLAND support@innovative-technology.co.uk SPAIN soporte@automated-transactions.es UNITED STATES OF AMERICA supportusa@bellis-technology.com REST OF THE WORLD sales@innovative-technology.co.uk Copyright Innovative Technology Ltd 2008 GA717...
Maximum Current Sink CAUTION · If the input voltage falls below 11.5 V the BV100 may not operate correctly (will reject notes). The front bezel lights will flash to indicate incorrect conditions. · It is recommended that the power supply used can supply at least 2.5 amperes.
Secure lock for the cash box A lock can be fitted to the BV100 to secure the cash box in place. A lock such as Camlock, product reference 2181D can be used.
Page 7
110 V AC supply. · Low power option The BV100 has a low power option to reduce the power consumption when idle. To learn more about the low power option, please refer to the Chapter 5.
4.2.1 PORTS AND BUTTONS The BV100 interface connector is located on the left side of the unit; it has 16 pins (see Figure 2), refer to Table 6 for the pin allocation. Two are used for the 0V and +12V power supply and there are five outputs and five inputs, the remaining four pins are reserved for factory use and should not be connected.
Inhibit channel 3 by holding this pin HIGH Inhibit channel 4 by holding this pin HIGH BV100 is validating and stacking output. Active low while the BV100 is reading, transporting or stacking a note Operate Escrow function by holding LOW (see Appendix B –...
Press the Configuration Button twice within half a second whilst the BV100 is powered up. The BV100 Bezel LED will then perform a series of flashes to indicate the current settings within the validator. (See Program Check Procedure, Appendix D - Configuration Cards)
· Open standard for universal use. For detailed information and full protocol specification please refer to SSP Interface Specification ITL (GA138), this is available from the ITL website www.innovative- technology.co.uk. To help in the software implementation of the SSP, ITL can provide DLL controls and Visual Basic applications on request.
4.3.3 MULTI-DROP BUS/INTERNAL COMMUNICATIONS PROTOCOL (MDB/ICP) To use the MDB mode an MDB BV100 or an IF5 interface box can be used. The MDB interface must be programmed into the validator via the Configuration Cards (See Appendix D - Configuration Cards) or via the ITL BNV Currency Manager program.
SSP interface is recommended. CAUTION · The BV100 does not support the simple serial data out only mode as available on NV4 and earlier models NV2 and NV3. It only supports the serial data input/output mode. · The host machine does not echo messages back to the validator.
Busy Output: (Pin 9). This is a general-purpose busy signal. It is active low while the BV100 is in operation. BV100 Operations Manual Copyright Innovative Technology Ltd 2008...
30 second time-out. Setting high all the inhibits causes a note reject. In the event of a note being forcibly removed from the mouth of the BV100 during the 30- second interval, the BV100 will go out of service for 45 seconds.
BV100 can be set to give a binary pattern output on the four parallel output pins. If the BV100 is set to binary mode it will issue the vend signals as a binary pattern on the parallel outputs for 100 ±...
Note: Channels higher than four cannot be individually inhibited, but will be globally inhibited if inhibits 1 to 4 are inhibited. It is possible to operate the BV100 in Low power mode with the Binary interface. For further details please see the next chapter.
Low power Mode can be used with all none serial communication protocols to reduce the power consumption of the BV100 when idle. When the BV100 is in this state the current consumption is reduced. The BV100 goes into low power mode approximately 6 seconds after the validator is powered up and remains in this state until a note is entered (Time A, Figure 10).
(Time A). When a note is inserted under the front sensor the BV100 wakes up and the busy line goes low to indicate that the validator is in use. The busy line remains low during the validating and stacking process and once the note has been successfully validated and stacked the vend line goes low to issue the credit.
The BV100 has an in-built self-calibration system that maintains the optical sensors at their best operating point. However if the BV100 is disassembled for any reason it will need to be re-calibrated. Re-calibration may only be performed under license from ITL, contact support@innovativetechnology.co.uk for further details.
Motor Foreign object or continues to note is stuck in the note path Copyright Innovative Technology Ltd 2008 Corrective Action Check that the required dataset is programmed into the validator using the validator manager software. Check that the required note denomination and issue is included in the currency file using the validator manager software.
(see the General Description chapter for operating system requirements). The BV100 can be connected directly via the USB port, or with either a DA1 kit fitted to the serial port or DA2 kit fitted to the USB port. (See Appendix F – Interface Tools DA1 – DA2)
Page 24
BV100 Operations Manual Internet Website Support The Innovative Technology Ltd website provides the means to download new and updated currency sets and new versions of firmware for the BV100. You can obtain these along with technical bulletins by visiting www.innovative-technology.co.uk E-mail Support If the data you require is not available over the Internet Innovative Technology supports an e-mail system to help customers with unusual requirements.
BV100 Operations Manual APPENDIX A – HOW TO ORDER A BV100 VALIDATOR To order a validator, please print and fill the order form, presented in the next page, and send it to our nearest office. You may send it by fax or email. To find our contact information, please go to our website or refer to the introduction chapter in this document.
9.2 APPENDIX B – BV100 MECHANICAL INSTALLATION DRAWING NUMBER GA700 In line with continued product development Innovative Technology Ltd reserves the right to change specification without prior notice. ACCEPTS NOTES UP TO: 1. 66 mm x 160 mm LONG 2. 72 mm x 160 mm LONG...
7) If an error occurs has occurred the card will be rejected and the bezel LEDs will flash slowly a number of times to indicate the cause of the error. (see table below) 8) important check that the configuration requested has been set in the BV100 before use.
Page 29
BV100 Operations Manual Program check procedure To check settings on a programmed unit: Power on unit Click program set button on unit twice (like double click on mouse) Monitor bezel led and check flash codes Flash Pulse Pulse count high...
Page 31
Below are some typical examples of completed Configuration Cards. Note: These Configuration Cards are samples and should not be copied for programming use. Please see document GA713 for useable cards Parallel Binary Copyright Innovative Technology GA717...
Page 32
Note: These Configuration Cards are samples and should not be copied for programming use. Please see document GA713 for useable cards. Unencrypted ccTalk Pulse – Pulse width Encrypted ccTalk 50/100 mS with 16-bit Checksum 4 Pulses per Dollar Copyright Innovative Technology GA717...
Page 33
Note: These Configuration Cards are samples and should not be copied for programming use. Please see document GA713 for useable cards. SIO 300-Baud SIO 9600-Baud SIO 300-Baud SIO 9600-Baud Starts Disabled Starts Disabled Copyright Innovative Technology GA717...
In the event of a note being forcibly removed from the mouth of the BV100 during the 30 second interval, the BV100 will go out of service for 45 seconds.
NOTE: The Validator must be in Programming mode when connected to a computer and then returned to the Original Settings when the download is complete. Figure 12 - Connecting DA1 to BV100 and PC for upgrading Validator programs Copyright Innovative Technology...
BV100 Operations Manual Connecting a DA2 to a validator and PC Figure 13 - Connecting DA2 to a BV100 and PC for upgrading Validator Programs Software Installation DA1 - To install the ITL BNV Download Manager Software insert the CDROM into the correct PC drive.
BV100 Operations Manual GENERAL INDEX bezel button cash ccTalk communication connector consumption credit hold function escrow humidity interface multi-drop bus protocol Smiley Secure Protocol status supply temperature voltage Windows Copyright Innovative Technology PAGE 5, 6, 8, 10, 16, 18, 22, 23, 25, 28, 29, 39...
Page 47
DRAWING NUMBER GA705 BV100 Operations Manual REVISION HISTORY INNNOVATIVE TECHNOLOGY LTD TITLE BV100 OPERATIONS MANUAL DRAWING NO AUTHOR GA717 ISSUE RELEASE DATE 10/10/07 04/12/07 Copyright Innovative Technology DATE FORMAT 10/10/07 MS Word 2000 MODIFIED BY COMMENTS First Draft First Release...