GA 713 BV Configuration Option Progamming
Insert this end first
SSP
PULSE
MDB
IF 30
IF 31
CCTALK
SIO
PARALLEL
SP 4
NIS
IF 32
I/F Spare 1
I/F Spare 2
I/F Spare 3
High 50ms
High 100ms
Low 50ms
Low 100ms
1
4
2
8
Bill 1
Bill 5
Bill 2
Bill 6
Bill 3
Bill 7
Bill 4
Bill 8
High Speed
cctalk plain
Start Disabled
cctalk 8 bit chk
Low Power
Binary
Credit Hold
option spare 3
66mm
Instructions for use
1 - Select correct width card for bezel. Cut card around
outline - check measurements as printed. Check print
options 'Page scaling' is set to 'None' when printing a pdf
file to ensure correct size.
2 - Fill in sections as required. Take care to fill in the
sections correctly, keep inside the lines and fill boxes fully
as example below:
GOOD
3 - Power-up BV and allow to reset.
4 - Click 'Function' button on BV to access Configuration
Mode, BV bezel LEDs should be flashing at 1 second
interval.
5 - Enter card into BV in direction indicated by arrows.
6 - Card will be rejected and if configuration was good the,
bezel LEDs will flash at a fast rate while programming takes
place. TAKE CARE TO ENSURE THE POWER IS NOT
REMOVED AT THIS STAGE, THE BV MAY SUFFER
PERMANENT DAMAGE !! The BV will then reset.
7 - If an error has occurred, the card will be rejected and the
bezel LEDs will flash slowly a number of times to indicate
the error cause. (See table below for codes).
8 - IMPORTANT - CHECK THAT THE CONFIGURATION
Flash
Error
______________________________________________
2
Invalid card read - card entered wrong way round,
card mis-read or card wrong version.
______________________________________________
3
No interface selection was detected on card.
______________________________________________
4
Multiple interface selection detected.
______________________________________________
5
Invalid interface selected - the selected interface is
not available for this BV.
______________________________________________
6
Selected interface not compatible with BV version.
______________________________________________
7
Pulse configuration error. Selected pulse options
invalid.(e.g. multiple pulse per dollar)
______________________________________________
8
ccTalk configuration error. Selected cctalk options
invalid. (cctalk 8 bit chk not allowed without ccTalk
Plain.)
______________________________________________
9
Low power mode not available on this BV version.
_______________________________________
OK
BAD
GA713-1-7