8. INSTRUCTIONS FOR USE
1.
Switch on the main switch, the display will light up and the unit is ready to input
the operating data, touch the display to access the main menu
2.
Click the central icon ARCHIVE, select the desired working cycle or create a new
one if the cycle had already been stored and data should not be modified, the
start up procedure can be activated right away by pressing START at the top
3.
Open the lid to access the inside of the working chamber and position the objects
to be treated, then close it completely (in case the lid is not fully closed the
working cycle will not start)
4.
Press the green start up key.
When the lid is opened the cycle will be immediately interrupted and once closed it will restart from the step it
had been cut off.
Once the cycle is definitively completed, the unit will emit a sequence of sound signals. When the lid is opened to
pick up the object, parameters will be reset to zero and the furnace is ready for a new cycle.
In case of voltage drop during the cycle, it will cause it to stop permanently and can not be recovered, as a
consequence it is recommended to protect the unit with an Uninterrupted Power Suppply (UPS) to avoid
wasting the objects as a result of an incomplete treatment (in any case a structural verification of the treated
objects is always recommended).
9. CHECK OF LED CONSUMPTION
The partial or complete deterioration in performance of the UV LEDs will cause the failure or partial curing of the
treated objects, the result is clearly visible (the object is not hardened or moist) or emerging in the following
treatments (finishing). To help prevent this problem it is necessary to check always the efficiency (test cycle and
visual inspection of the treated objects). In addition the software manages a control system on LED consumption.
As the deterioration level is approaching, a warning symbol will appear on the display; operation is
still allowed by slightly extending the working time. Spares replacement is promptly recommended.
After an additional short period, a ban symbol is shown locking the unit and forcing the technical
intervention.

10. MAINTENANCE

/!\
Before carrying out any maintenance operation inside the machine, unplug the electric
ATTENTION:
cable from the socket; in such a way the machine will be completely insulated from the
electric wiring system. If you still have any doubts, difficulties or any possibility of mistake,
contact our Technical Service to avoid any risks or damages.
Any technical intervention involving to remove the protections and to manipulate the
machine internal components can be carried out exclusively by skilled personnel or staff
trained by the Manufacturer.
Cleaning of the working chamber
It is advisable to keep always clean the internal surfaces of the working chamber to allow the correct refraction of
the emitted rays; be careful to use exclusively non-aggressive liquid detergent specific for glass and PMMA
(absolutely with neither abrasive components nor alcohol).