To unlock the tablet and access the applications, press the Lock icon (padlock).

Preparing to Test

NOTE: A coalescing filter MUST be used when operating the Brake Pro™. Failure to do so
will increase the chance of contamination damaging the internal electronic components.
Contamination is NOT covered by warranty.
IMPORTANT SAFETY NOTICE: Quick connect fittings must always be used in accordance with good
practice and the instructions and regulations of the manufacturer and your employer. Always ensure
connecting fittings are firmly and properly engaged, locked in place, and cannot accidentally become
disengaged. An improperly installed fitting may be dangerous and could cause serious injury or death
if it becomes disengaged while pressurized. I S Technology Solutions does not accept responsibility
for the installation of improper fittings or the misuse of fittings.

Attaching Air Hoses for the Daily Test

To prepare for the 2 Pressure End-Of-Car Daily Test:
1. Connect the coalescing filter to the SUPPLY fitting on the Brake Pro™.
2. Connect the shop air supply hose to the coalescing filter. Supply must be greater than the
Operating pressure (90psi).
3. Connect the BLACK Brake Pipe hose with Gladhand to the Brake Pipe fitting on the Brake
Pro™.
4. Connect the BLACK Brake Cylinder hose to the Brake Cylinder fitting on the Brake Pro™.
5. Insert the dummy coupling into the gladhand.
6. Connect the Brake Cylinder Hose to the pressure tap on the dummy coupling.
7. Run the Daily Test on the application from the Main Menu and select 2P EOC.
8. When finished, disconnect the hos from the dummy coupling pressure tap. Remove the
dummy coupling from the gladhand.
6