  • Page 1 User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Multi-parameter Patient Monitor Deluxe-80 User Manual Version: 1.5 Issued by: Sara Lo Date: 5/11/2020 Reviewed by: Albert Huang Date: 5/11/2020 Document No: UM-PM8-201507-01 North-Vision Tech. Inc. 2460 - 1 -...
  • Page 2 Part1: General requirements for safety)and MDD 93/42/EEC. It complies with both international and enterprise standards and is also approved by the Food and Drug Administration, Ministry of Health and Welfare. The Manual is written for the current Deluxe-80 Multi-Parameter Patient Monitor The Manual describes, in accordance with the Vital Signs Monitor’s features and requirements, main...
  • Page 3 User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Instructions to User Dear Users, Thank you very much for purchasing our product. Please read the following information very carefully before using this device. Read these instructions carefully before using this monitor. These instructions describe the operating procedures to be followed strictly.
  • Page 4: Table Of Contents

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Table of Contents CHAPTER 1 OVERVIEW 1.1 F EATURES 1.2 P RODUCT AME AND ODEL 1.3 I NTENDED NORMAL WORKING ENVIRONMENT 1.5 S YMBOLS ON THE ONITOR CHAPTER 2 OPERATING PRINCIPLE 2.1 C...
  • Page 5 User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. 6.1 P ACKAGING 6.2 A CCESSORIES CHAPTER 7 WORKING PRINCIPLE 7.1 T NIBP M RINCIPLE OF EASUREMENT 7.2 P NIBP M OINTS TO BE NOTED IN EASUREMENT 7.2.1 Operation instructions 7.2.2 Clinical Limitations 7.3 T...
  • Page 6: Chapter 1 Overview

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Chapter 1 Overview 1.1 Features Blood Pressure, SpO and Pulse Rate are displayed by big, bright digital LEDs; Plethysmogram and system parameters are displayed on dot matrix LCD screen; Accurate NIBP measurement with hardware and software over-pressure protection;...
  • Page 7: Symbols On The Monitor

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. 1.5 Symbols on the Monitor - 7 -...
  • Page 8: Chapter 2 Operating Principle

    The overall structure of the monitor is shown in Fig. 2.1. Figure 2.1 Deluxe-80 Multi-Parameter Patient Monitor is module designed product; it consists of NIBP module (optional), SpO2 module (optional), main control unit, printer module, display panel and power supply block etc.
  • Page 9: Chapter 3 Installation And Connection

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Chapter 3 Installation and Connection 3.1 Appearance 3.1.1 Front Panel Figure 3.1 Front panel illustration Module Configuration Instructions According to different needs, user can customize the module configuration by choosing the necessary modules. This manual shows how to use the monitor of this model with SpO2and NIBP modules.
  • Page 10 User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. NIBP measurement; they will be displayed alternately. The format of NIBP measuring time is “hh:mm”. Note: two formats to display NIBP value: “×××mmHg” and “××.×kPa”. Refer to section “4.4.2 NIBP Setup” to set the unit of NIBP value; the conversion relation between “mmHg”...
  • Page 11: Side Panel

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. 19 : DC Power indicator AC Power DC Power Descriptions indicator indicator this device is using mains power supply (green) (green) the battery is being used (green) the battery is being used, but battery...
  • Page 12: Installation

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Introduction to the rear panel: 1 Handle 2 Fan 3 Nameplate 4 Fuse holder: FUSE T3.15A 5 AC power supply socket 6 Loudspeaker 7 Mounting hole for hanging the monitor 8 Data interface...
  • Page 13: Starting The Monitor

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. 3.2.3 Starting the Monitor The system performs self-test and enters initial display after switching on the monitor, and the orange alarm indicator blinks to inform that the user can begin operating it.
  • Page 14: Spo Sensor Connection

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. NIBP monitoring is prohibited to those who have severe hemorrhagic tendency or with sickle cell disease, or partial bleeding will appear. Pay attention to the color and sensitivity of the limb when measuring NIBP; make sure the blood circulation is not blocked.
  • Page 15: Loading Printing Paper

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Figure 3. 5 Neonate SpO2 sensor placement Safety Introductions for SpO2 Monitoring Continuous use of finger clip SpO2 sensor may result in discomfort or pain, especially for those patients with microcirculatory problem. It is recommended that the sensor should NOT be applied to the same finger for over two hours.
  • Page 16: Battery Installation

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. compartment. 5. Pull the paper out of paper slot on the shield. 6. Move the tab of the rubber roller lock 90° downwards to lock it. 7. Put the shield back in position and secure it.
  • Page 17 User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Figure 3.7 Battery Installation Note: Do not insert battery terminal with its polarities reversed, or the monitor can not ● be started. Please take out the battery before transport or storage.
  • Page 18: Chapter 4 Operations

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Chapter 4 Operations 4.1 Initial Monitoring Screen When the module configuration is “SpO2+NIBP”, once powered up, the LCD will display the initial monitoring screen with SpO2 plethysmogram, this is the default display screen.
  • Page 19: Operation Instructions

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Figure 4.2 Probe Off Prompt Info: Status or event indication segment: This segment will display the probe status, alarm silence counting-down timer, over limit warning and other error messages for technical warning. If more than one event occurs or more status appears, the indication message will be displayed alternately at this segment.
  • Page 20: Spo2 Trend Graph Display

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. 4.2 SpO2 Trend Graph Display Short pressing “ Display” key to shift the screen view to trend graph display screen, as shown in Figure 4.3. Figure 4.3 Trend Graph “12 hours”: the trend length of trend graph; three options: “12”, “24” or “96” hours;...
  • Page 21: Nibp List Screen

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. “ ” key: start/cancel NIBP measurement “ ” key: alarm silence switch; press it to enable/disable alarm silence. 4.3 NIBP List Screen Short pressing “Display” key to shift the screen to NIBP List screen, as shown in Figure 4.4.
  • Page 22: Setup Menu Screen

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. 4.4 Setup Menu Screen At any display view screen, long time press“ Display” key to shift the screen to Setup Menu screen, as shown in Figure 4.5. All the functional parameters of the system can be set through Setup Menu.
  • Page 23: Nibp Setup

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Screen Description: “SpO2 ”: SpO alarm switch; “” indicates SpO2 alarm is on; “ ” indicates SpO2 alarm is off. “SpO2 Hi”: high limit of SpO2 alarm; range: “1~100”. “SpO2 Lo”: low limit of SpO2 alarm; range: “0~99”.
  • Page 24: Nurse Call

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. “ ” indicates systolic pressure alarm is off. “SYS Hi”: high limit of systolic pressure alarm; range: “32~250” mmHg. “SYS Lo”: low limit of systolic pressure alarm; range: “30~248” mmHg. “DIA ”: diastolic pressure alarm switch; “ ” indicates diastolic pressure alarm is on;...
  • Page 25: System Setup

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Note: Nurse Call function can not be regarded as main alarm notice method, please do not entirely relay on it. You should combine parameter values with alarm level and patient’s clinical behavior and symptom to determine patient’s status.
  • Page 26: Patient Info

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. 4.4.5 Patient Info Figure 4.10 Patient Info Screen “ID”: change or set current patient’s ID number, 0~100 adjustable; “category”: change or set the category of current patient; three options “adult”, “pediatric” and “neonate”, the default is “adult”.
  • Page 27: Power Saving Mode

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. 4.5 Power Saving Mode At any display view screen, you can make the monitor stay in power saving mode for power saving. Short time press power button to shift screen to “Power Saving Mode” display screen, as shown in Figure 4.12.
  • Page 28: Chapter 5 Technical Specifications

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Chapter 5 Technical Specifications 5.1 NIBP Monitoring A. Technology: Oscillometric method. B. Cuff inflation time: ≤10seconds (typical adult cuff) C. Air release time while the measurement is canceled: ≤2 seconds (typical adult cuff) D.
  • Page 29 User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Safety standard IEC 60601-1 The type of protection against electric shock ClassⅠequipment. The degree of protection against electric shock Type BF applied parts Protection against ingress of water IPX1 5.6 Default Alarming Values of All Parameters...
  • Page 30: Chapter 6 Packaging And Accessories

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Chapter 6 Packaging and Accessories 6.1 Packaging The product is packed in high quality corrugated cartons with foam inside to protect the equipment against damage in the shipping and handling process.
  • Page 31: Chapter 7 Working Principle

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Chapter 7 Working Principle 7.1 The Principle of NIBP Measurement Blood pressure may be measured in an invasive way (whereby the sensor will be inserted into blood vessel directly) or a non-invasive way. The non-invasive way includes several methodologies, such as the Korotkoff Sound Method and oscillating method.
  • Page 32: Clinical Limitations

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. cuff will be automatically adjusted according to the previous measure. Generally, the initial inflation pressure is 180mmHg (for the adult mode) or 100mmHg (for the pediatric mode) or 80 mmHg (for the neonate mode) when it is powered on. Following that, 50mmHg (for the adult mode) or 30mmHg (for pediatric mode) or 10mmHg (for the neonate mode) will be added on the basis of the last measurement of systolic pressure.
  • Page 33: Clinical Limitations

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. 4. Do not fix the SpO2 sensor with adhesive tape, or else it may result in venous pulsation and consequential inaccurate measurement result of SpO2. 5. Make sure the optical path is free from any optical obstacles like adhesive tape.
  • Page 34: Chapter 8 Troubleshooting

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Chapter 8 Troubleshooting 8.1 No Display on the Screen Shut down the machine and unplug the power. Use a universal meter to check if the outlet has proper voltage, if the power cable is in good condition, and if the power cable is properly connected with this apparatus or outlet.
  • Page 35: Chapter 9 Maintenance

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Chapter 9 Maintenance 9.1 Service and Examination 9.1.1 Daily Examination Before using the monitor, the checks below should be carried out:  Check the monitor for any mechanical damage;  Inspect the exposed parts and the inserted parts of all the leads, and the accessories;...
  • Page 36: Cleaning, Sterilization And Disinfection

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. It is recommended to use the battery once a month to ensure its strong power supply capacity and long service life, and recharge it after running out of the power. In order to maintain battery supply time and prolong battery lifetime, please use the battery once a month and do not charge it until it is used up each time.
  • Page 37: Appendix

    User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. This monitor should be transported by land (vehicle or railway) or air in accordance with the contractual terms. Do not hit or drop it with force. Prompt information explanations Mute C-D: XXX seconds...
  • Page 38 User Manual for Multi-parameter Patient Monitor North-vision Tech. Inc. Manufacturer North-vision Tech. Inc. Address: 1st Fl., No.15, Gongye E. 2nd Rd., East Dist., HsinChu City 30075, Taiwan R.O.C. International Sales North-vision Tech. Inc. Address: 1st Fl., No.15, Gongye E. 2nd Rd., East Dist., HsinChu City 30075, Taiwan R.O.C.

Table of Contents