Summary of Contents for North-Vision Tech Handheld-100

  • Page 1 User Manual for Handheld Pulse Oximeter North-vision Handheld Pulse Oximeter Handheld-100 User Manual Version: 2. Issued by: Sara Lo Date: 5/11/2020 Reviewed by: Albert Huang Date: 5/11/2020 Document No: UM-HO1-201212-01 North-Vision Tech. Inc. 2460...
  • Page 2 User Manual for Handheld Pulse Oximeter Instructions to User Dear Customer, Thank you for purchasing this quality product. Please read the manual very carefully before using this device. Failure to follow these instructions can cause measuring abnormality or damage to the Oximeter.
  • Page 3 User Manual for Handheld Pulse Oximeter Instructions for Safe Operation  Check the device to make sure that there is no visible damage that may affect user’s safety and measurement performance. It is recommended that the device should be inspected minimally before each use. If there is obvious damage, stop using the device.
  • Page 4 User Manual for Handheld Pulse Oximeter  For the individual patients, there should be a more prudent inspecting in the placing process. The sensor cannot be placed on the edema and tender tissue.  The local law should be followed when disposing of the expired device or its accessories.
  • Page 5 User Manual for Handheld Pulse Oximeter and follows the provisions of the council directive MDD93/42/EEC. Caution: U.S. federal law restricts this device to sale or use by or on the order of a physician.
  • Page 6: Table Of Contents

    User Manual for Handheld Pulse Oximeter Table of Contents 1 Overview ................. 1 1.1 Appearance............... 1 1.2 Product Name and Model..........2 1.3 Structure................3 1.4 Features................3 1.5 Intended Use..............3 1.6 Working Environment............3 2 Installation of Battery and Holder.
  • Page 7: Overview

    User Manual for Handheld Pulse Oximeter 1 Overview 1.1 Appearance Reserved port Data interface Display screen Power/Back Navigation keys Recall/Mute Mode/OK probe connector Figure 1-1 1. Display screen: display SpO plethysmogram and parameter values. 2. Navigation key:  : Up/Left/Increase...
  • Page 8: Product Name And Model

    90s. After this mute period (90s), then the indication sound will resume. 8. Icon: “SpO ”: SpO Probe Connector. 1.2 Product Name and Model Name: Handheld Pulse Oximeter Model: Handheld-100...
  • Page 9: Structure

    User Manual for Handheld Pulse Oximeter 1.3 Structure It consists of the main unit and SpO probe. 1.4 Features  It is lightweight, small in size and easy to carry  Color LCD to display plethysmogram and parameters  Monitor SpO2 and Pulse Rate simultaneously ...
  • Page 10: Installation Of Battery And Holder

    User Manual for Handheld Pulse Oximeter 2 Installation of Battery and Holder 1) Open the rear panel with coin or an ordinary flat screwdriver, as shown in Figure 2-1. Figure 2-1 2) AA Alkaline batteries: ① If AA alkaline batteries (non-chargeable) are provided, then according to the polarity mark, insert three AA batteries into battery house, as shown in Figure 2-2.
  • Page 11 User Manual for Handheld Pulse Oximeter 3) Close the battery cover and lock it. 4)Fixing Holder, as shown in figure 2-3. Notes: ① When the device is provided with AA alkaline batteries and it shows low battery, the user should replace the batteries in time.
  • Page 12: Spo Probe Connection

    User Manual for Handheld Pulse Oximeter  If the battery is damaged, please replace it with the same model AA alkaline battery provided by the same manufacturer. 3 SpO Probe Connection probe to the connector labeled “SpO ” at the Connect the SpO right side of the Oximeter.
  • Page 13 User Manual for Handheld Pulse Oximeter 4. Avoid placing the sensor on the same limb which is wrapped with a cuff for blood pressure measurement or during venous infusion. 5. Do not let anything block the emitting light from the sensor. 6.
  • Page 14: Operation

    User Manual for Handheld Pulse Oximeter 4 Operation 4.1 Power on/off the Oximeter ➢ Long " power/back key for 1~2 seconds, then the oximeter will be powered on or off. ➢ During measurement, if the "Probe off" status is sustaining for longer than one minute, and if there is no any key operation for one minute, then the device will power off automatically.
  • Page 15 User Manual for Handheld Pulse Oximeter user can turn on the indication sound by short pressing recall/mute " " key. During the measurement, over-limit event or probe off event can activate the alert indication sound. “ ”: Memory full icon; if the memory is full, the memory full icon "...
  • Page 16: Display Screen With Pi Value

    User Manual for Handheld Pulse Oximeter 4.3 Display Screen with PI Value On the default display screen, press “/” Navigation key to shift screens between default screen and display screen with PI value. The display screen with PI value is shown below. Figure 4-2 Display Screen with PI Value 4.4 Menu Setup On the above mentioned screens, longtime press “...
  • Page 17 User Manual for Handheld Pulse Oximeter details. ➢ “Upload data”: enter into data uploading state, refer to Chapter 4.4.2 for details. ➢ "Default": enter into the factory default setting, refer to Chapter 4.4.3 for details. “Version”: for viewing version number of the software, ➢...
  • Page 18 User Manual for Handheld Pulse Oximeter Operation Instructions: ➢ Patient: according to the type of SpO probe, the matched patient type should be selected, there are two options:"ADU " for adult, and " NEO " for pediatric. ➢ Lo-Limit: SpO low limit setting;...
  • Page 19 User Manual for Handheld Pulse Oximeter the Year of the date; Press / (Navigation key) to adjust year. 2) ” (Power/back) key or ” (Mode/OK) key to Press 3) confirm and exit from date setting. The procedures of adjusting Month value and Day value 4)...
  • Page 20 User Manual for Handheld Pulse Oximeter 5) When the option is set to “OFF”, the device will not store the measuring data. ➢ Power saving: power saving setting; two options: "on" and "off". The factory default setting is "on". If the power saving mode is on during measurement, and there is no key operation for 2 minutes, the screen display will be dim for power saving.
  • Page 21 User Manual for Handheld Pulse Oximeter Figure 4-5 Connecting Status Screen 4.4.3 Default On the menu screen, select "Default " and then short time press " "key for entering into default setting screen (as shown in Figure 4-6). Press the Navigation "...
  • Page 22: Data Recall

    User Manual for Handheld Pulse Oximeter display language changes to English. ➢ In English version: on main menu screen, select "Simplified Chinese" and then short time press " key, the display language changes to Simplified Chinese. 4.4.5 Version On the menu screen, select “VERSION” and then press “ ”...
  • Page 23 User Manual for Handheld Pulse Oximeter 4.5.1 Data Recall Choose record in the record list, then press “ ”(mode/OK) key, the display screen will display trend graph, as shown in Figure 4- Figure 4-9A Trend Graph Display Screen Operation Instructions: •...
  • Page 24 User Manual for Handheld Pulse Oximeter Figure 4-9C Trend Graph Display Screen 4.5.2 Data Deletion On the menu screen, longtime press “ ” key and the records ” key again, an list will appear. At this time, longtime pressing message “Are you sure to delete all?” prompts on the screen, as shown in Figure 4-10.
  • Page 25: Technical Specifications

    User Manual for Handheld Pulse Oximeter 5 Technical Specifications A. Display Mode: Color dot-matrix LCD; B. Power Supply: Supply voltage: d.c. 4.5V(3 AA alkaline batteries) Operating current: ≤180mA Continuous working time: >30 hours C. SpO Measurement Transducer: dual-wavelength LED sensor with wavelength: Red light: 663 nm, Infrared light: 890 nm.
  • Page 26 User Manual for Handheld Pulse Oximeter Operating Humidity: 15%~93% Atmospheric pressure: 70kPa~106kPa Note: portable and mobile RF communications equipment may affect the performance of the Oximeter. G. Data Update 8 beats moving average for both SpO and pulse rate readings H.
  • Page 27 User Manual for Handheld Pulse Oximeter The device is not intended for use in the environment with rich oxygen or ignitable gas. Mode of operation: Continuous operation Electro-Magnetic Compatibility: Group I, Class B...
  • Page 28: Over-Limit Indication

    User Manual for Handheld Pulse Oximeter 6 Over-limit Indication 6.1 Limit settings ➢ low limit setting range: 50% ~ 99%. ➢ Pulse Rate limits setting range: High: 100bpm--240bpm Low: 30bpm--99bpm During the measurement, if the measured value exceeds the preset value, the alert beeping sound will be activated, the value that is over-limit will blink at the same time.
  • Page 29: Packing List

    User Manual for Handheld Pulse Oximeter display screen. The alert sound starts (interval is 5 seconds) and lasts for about 1 minute. If the probe is still off, the Oximeter will power off automatically. 7 Packing List 1. Main unit 2.
  • Page 30: Repair And Maintenance

    User Manual for Handheld Pulse Oximeter 8 Repair and Maintenance 8.1 Maintenance The expected service life (not a warranty) of this device is 5 years. In order to ensure its long service life, please pay attention to the maintenance; ● Please change the batteries when the low-voltage indicator appears.
  • Page 31: Troubleshooting

    User Manual for Handheld Pulse Oximeter 9 Troubleshooting Trouble Possible Reason Solution 1. The finger is not 1. Place the finger Unstable placed far enough correctly inside and try inside. again. Pulse Rate 2. The finger is 2. Reduce patient display shaking or the patient movement.
  • Page 32: Appendix

    User Manual for Handheld Pulse Oximeter Appendix Key of Symbols Description Symbol %SpO The oxygen saturation Perfusion Index Symbols Pulse rate (Unit: beats per minute) on the Low battery voltage screen Battery fully charged icon Speaker mute icon Memory full (Pediatric/Adult) Patient type...
  • Page 33 User Manual for Handheld Pulse Oximeter Symbol Description probe connector Power/Back Key Mode/OK Key Symbols Recall/Mute Key on the / Navigation Key panels Data Interface CE mark Serial number Date of manufacture Authorized representative in the European community Manufacturer (including address) With Type BF applied part See User Manual Disposal of this device according...
  • Page 34 User Manual for Handheld Pulse Oximeter Common Knowledge 1 Meaning of SpO is the saturation percentage of oxygen in the blood, so called O concentration in the blood; it is defined by the percentage of oxyhemoglobin (HbO ) in the total hemoglobin of the arterial blood.
  • Page 35 User Manual for Handheld Pulse Oximeter contrast, hemoximeters report fractional oxygen saturation – a percentage of all measured hemoglobin, including dysfunctional hemoglobin, such as carboxyhemoglobin or metahemoglobin. Clinical application of pulse oximeters: SpO is an important physiological parameter to reflect the respiration and ventilation function, so SpO monitoring used in clinical becomes more popularly, such as monitoring the patient with serious...
  • Page 36 User Manual for Handheld Pulse Oximeter such as nail enamel or color skin care  Excessive patient movement  Placement of a sensor on an extremity with a blood pressure cuff, arterial catheter, or intravascular line  Exposure to the chamber with High pressure oxygen ...
  • Page 37 User Manual for Handheld Pulse Oximeter...
  • Page 38 User Manual for Handheld Pulse Oximeter Manufacturer North-vision Tech. Inc. Address: 1st Fl., No.15, Gongye E. 2nd Rd., East Dist., HsinChu City 30075, Taiwan R.O.C. International Sales North-vision Tech. Inc. Address: 1st Fl., No.15, Gongye E. 2nd Rd., East Dist., HsinChu City 30075, Taiwan R.O.C.
  • Page 39 User Manual for Handheld Pulse Oximeter European Representative: CMC Medical Devices & Drugs S.L. C/Horacio Lengo N 18, CP 29006 Malaga, Spain TEL: +34951214054 FAX:+ 34952330100...