Screen Control Codes - IEE 036X2-121-11120 Reference Manual

Iee 036x2-121-11120 pole display: reference guide
Table of Contents

Advertisement

4.5

Screen Control Codes

[A
(RS) = High for the following Control Codes]
0
30h
31h
Character Code
00h
01h
02h
04h
32h
33h
34h
35h
Industrial Electronic Engineers, Inc.
Van Nuys, California
04/10/02
Set Display Screen or Column Brightness Level
Sets the display brightness level using a 3 byte command consisting of control code 30h, column
ID, and brightness level. Column ID code FFh sets all columns. Brightness levels range from 00h
(brightest) through 07h (dimmest). (Default is 00h)
Brightness levels must be set by columns rather than by
characters because of the construction of the vacuum
fluorescent tube.
Begin Blinking Character(s)
Sets the start of blinking character(s) or underbar(s) and the blink rate using a 2 byte command
consisting of control code 31h and blink code. Subsequent characters will blink until Control Code
32h is sent. (If a character is written at the current cursor location, that character will blink).
The "Underbar" and "Both" code sets apply only to 36X2–151–05240.
Rate
OFF (Default) 60h
1 Hz
2 Hz
4 Hz
End Blinking Character(s)
Sets the end of blinking character(s) at the current cursor location. Subsequent characters will not
blink until Control Code 31h is sent. (A character written to the current cursor location will not
blink).
If a blinking character is overwritten by a non–blinking character, or if the Erase Line command is
executed, the blink attribute is turned off.
Blank Display Screen
Sets the display screen to OFF. Data and attribute settings are not affected.
Unblank Display Screen
Returns the display screen to ON after 33h.
Comma/Period/Triangle Function
35-01-n:
display character with period
n = display character 20-FF
35-02-n:
display character with comma
n = display character 20-FF
35-03-n:
display character with comma & period
n = display character 20-FF
35-04-n:
display character with triangle
n = display character 20-FF
Note
Underbar Code Rate
OFF
61h
1 Hz
62h
2 Hz
64h
4 Hz
SIZE
CODE IDENT NO.
A
05464
SCALE
N/A
REV
Both Code
Rate
80h
OFF
81h
1 Hz
82
2 Hz
84h
4 Hz
S036X2–XXX–XXXXX
SHEET
N
31 of 49