IEE 036X2-121-11120 Reference Manual

Iee 036x2-121-11120 pole display: reference guide
Table of Contents

Advertisement

Quick Links

APPLICATION
NEXT ASSY
FINAL ASSY
REV
M
G
SHEET
48
49
50
51
REV
G
G
G
G
SHEET
24
25
26
27
REV
N
N
G
G
CV
SHEET
1
2
3
R
PROJ. NO.
346
NOTICE IS HEREBY GIVEN THAT THIS DRAWING
IS PART OF A PROPRIETARY ITEM OWNED BY
INDUSTRIAL ELECTRONIC ENGINEERS, INC. AND
SHALL NOT BE REPRODUCED, OR COPIED OR USED AS THE
BASIS FOR MANUFACTURE OR
SALE OF APPARATUS WITHOUT WRITTEN
PERMISSION OF IEE, INC.
LTR
Initial Release. E.O. 30328
A
Correct typos \ E.O. 30353
B
Change Cable Part No. \ E.O. 30367
C
Add –106 & –151 to Tables and Outlines, Revise
Section 4, Correct Typo Sht. 40 \ E.O. 31107
D
Change -105 Current Ratings on Sht. 16
\E.O. 31186
E
Add -120, -121, -130, -134 & -160 to Tables and
Outlines, Revise Section 4.4 Sht 29 \ E.O. 32196
F
Correct -105 Outline Dimensions \ E.O. 32330
G
E.O. 32796
H
E.O. 33653
J
E.O. 34249
K
E.O. 34831
L
E.O. 34854
M
E.O. 35324
N
E.O. 35373
52
53
54
55
56
G
G
G
G
G
28
29
30
31
32
G
G
G
G
G
4
5
6
7
8
REVISION STATUS
CONTRACT
DRAWN
M. Englehart
07–26
D. McCoy
07–26
CHECK
APPROVED
B. Lo / 94–07–26
APPROVED
REVISIONS
DESCRIPTION
57
58
59
60
61
62
G
G
L
G
G
G
33
34
35
36
37
38
G
G
G
G
G
G
9
10
11
12
13
14
INDUSTRIAL ELECTRONIC ENGINEERS, INC.
Specification, VFD, Century Series,
Dot Matrix Modules
SIZE
CODE IDENT NO.
05464
A
SCALE
DATE
94–07–26
94–08–05
94–08–15
95–07–31
95–11–15
96-11-7
96-12-4
97-4-14
98-4-3
99-3-15
99-11-23
00-01-24
00-05-30
6-27-00
63
64
65
66
67
G
G
G
G
G
39
40
41
42
43
G
G
G
H
H
15
16
17
18
19
VAN NUYS, CALIFORNIA
S036X2
None
SHEET
APPROVED
B. Lo
M. Englehart
B. Lo
M. Englehart
B. Lo
B. Lo
B. Lo
B. Lo
B. Lo
B. Lo
B. Lo
B. Lo
B. Lo
B. Lo
68
69
70
71
G
N
J
G
44
45
46
47
G
G
G
G
20
21
22
23
1
OF
49

Advertisement

Table of Contents
loading

Summary of Contents for IEE 036X2-121-11120

  • Page 1 IS PART OF A PROPRIETARY ITEM OWNED BY INDUSTRIAL ELECTRONIC ENGINEERS, INC. AND SHALL NOT BE REPRODUCED, OR COPIED OR USED AS THE BASIS FOR MANUFACTURE OR DRAWN SALE OF APPARATUS WITHOUT WRITTEN PERMISSION OF IEE, INC. CHECK APPROVED B. Lo / 94–07–26 APPROVED DESCRIPTION —...
  • Page 2 PRODUCT SPECIFICATION Century Series Flip Dot Matrix ASCII VFD Modules REV. N...
  • Page 3: Table Of Contents

    LIST OF ILLUSTRATIONS ... 3 LIST OF TABLES ... 4 DEFINITIONS AND CONVENTIONS ... 5 1.0 SCOPE... 6 2.0 APPLICABLE DOCUMENTS... 6 3.0 CHARACTERISTICS ... 6 3.1 G ... 6 ENERAL 3.1.1 Environment... 6 3.1.2 Useful Life ... 6 3.1.3 Display Functions ... 6 3.1.4 Size and Weight ...
  • Page 4: List Of Illustrations

    Figure 3–1 Functional Block Diagram, Intel Mode 3–2 Functional Block Diagram, Motorola Mode 3–3 Functional Block Diagram, LCD Mode 3–4 ASCII Character Set 3–5 Cyrillic Character Set 3–6 European Character Set ... 3–7 Hebrew Character Set 3–8 Katakana Character Set ... 3–9 LCD (Hitachi) Character Set 3–10...
  • Page 5: List Of Tables

    Table 3–1 Physical Dimensions 3–2 Display Character Fonts ... 3–3 Display Supply Current ... 3–4 Connector Pin Assignments 3–5 Execution Times 4–1 Dot Data for User Defined Characters Industrial Electronic Engineers, Inc. Van Nuys, California 04/10/02 LIST OF TABLES Description SIZE CODE IDENT NO.
  • Page 6: Definitions And Conventions

    Conventions: First Line, Column, Bit or Position is 0 or 00h. Control Code names are italicized. Upper case A with subscript from 0 to 7 indicates an address bit from LSB to MSB. Upper case D with subscript from 0 to 7 indicates a data bit from LSB to MSB. Counting order is left–to–right, top–to–bottom.
  • Page 7: Scope

    SCOPE This document describes the complete performance and interface characteristics of the dot matrix family of Century Series Vacuum Fluorescent Displays (VFD). For the remainder of this document, the Century Series VFDs are referred to as the display. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein.
  • Page 8: Functional Block Diagram, Intel Mode

    (Not used in Serial Mode) Serial Input 8-Bit Bidirectional Data Bus +5 Vdc Industrial Electronic Engineers, Inc. Van Nuys, California 04/10/02 Display Tube Anode (Row) Drivers Microcontroller Logic Supply DC to DC & Filament Supply DC to AC Voltage Anode/Grid Supply Converter Figure 3–1 Functional Block Diagram, Intel Mode...
  • Page 9: Functional Block Diagram, Motorola Mode

    (Not used in Serial Mode) RD/WR Serial Input 8-Bit Bidirectional Data Bus +5 Vdc Industrial Electronic Engineers, Inc. Van Nuys, California 04/10/02 Display Tube Anode (Row) Drivers Microcontroller Logic Supply DC to DC & Filament Supply DC to AC Voltage Anode/Grid Supply Converter Figure 3–2...
  • Page 10: Functional Block Diagram, Lcd Mode

    RD/WR 8-Bit Bidirectional Data Bus +5 Vdc Note: CS must be grounded when using LCD Mode. Industrial Electronic Engineers, Inc. Van Nuys, California 04/10/02 Display Tube Anode (Row) Drivers Microcontroller Logic Supply DC to DC & Filament Supply DC to AC Voltage Anode/Grid Supply Converter...
  • Page 11: Size And Weight

    3.1.4 Size and Weight The physical dimensions of the displays vary with the size of the tube. The characteristics shown are for standard configuration display products, some options will affect these data. Model 036X2–100–05420 036X2–105–05220 036X2–106–04240 036X2–120–09120 036X2–121–11120 036X2–122–09220 036X2–124–09420 036X2–130–11220 036X2–134–11420 036X2–151–05240...
  • Page 12: Character Font Data

    3.1.5 Character Cell Features (Cont.) Hitachi (LCD) Mode: The Hitachi (LCD) mode character table also includes the ASCII and scientific character sets and several user definable character locations. The “special charcater set” present in the Motorola/Intel mode is absent, and certain characters from the U.S. ASCII set are different. The address A0h through DFh locations mimic the Katakana character set while address E0h through FFh locations comprise a unique Hitachi set.
  • Page 13 Figure 3–4 ASCII Character Set (with Scientific, Specials & UDC's) SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 12 of 49 04/10/02...
  • Page 14 Figure 3–5 Cyrillic Character Set Figure 3–5A Cyrillic Character Set (036X2-160-05440 ONLY) SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 13 of 49 04/10/02...
  • Page 15 Figure 3–6 European Character Set SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 14 of 49 04/10/02...
  • Page 16 Figure 3–7 Hebrew Character Set Figure 3–8 Katakana Character Set SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 15 of 49 04/10/02...
  • Page 17: Lcd (Hitachi) Character Set

    Figure 3–9 Hitachi (LCD) Character Set SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 16 of 49 04/10/02...
  • Page 18: Interfaces

    Interfaces 3.2.1 Power Interface The display power converter is a Constant Power configuration. Supply Voltage Damage may occur if the supply voltage exceeds 5.5 Volts dc or if data or control signals are applied prior to application of dc power. Supply Rise Time Supply Current: 036X2–100–05420...
  • Page 19: Data Interface

    3.2.2 Data Interface The displays accept either serial or parallel input data and control codes. Internal logic can interface to either Intel and Motorola processors and emulate equivalent Hitachi 44780 LCD features. 3.2.2.1 Serial Input Levels High (space/logic 0) Low (mark/logic 1) Baud Rate Selectable—1200, 9600 or 19200.
  • Page 20: Power/Data Connector

    The 36X2-134 model has a separate power connector J2 and the pin assignments are: IEE recommends that the user install a keying plug in the mating connector at the Pin 8 location. This will assure that the mating connector is always installed correctly and will avoid damage to the display.
  • Page 21: Connector Pin Assignments

    Intel Mode PIN NO. FUNCTION J1–1 DATA BIT 7 (MSB) J1–2 +5 VDC J1–3 DATA BIT 6 J1–4 +5 VDC J1–5 DATA BIT 5 J1–6 COMMON J1–7 DATA BIT 4 J1–8 REMOVED FOR KEYING J1–9 DATA BIT 3 J1–10 COMMON J1–11 DATA BIT 2 J1–12...
  • Page 22: Performance Characteristics

    Performance Characteristics Processor Power–up Cycle Part Number Blink Brightness Send Character Clear Cursor Locate Home Horizontal Scroll Reset Vertical Scroll Brightness Control Viewing Angle Dedicated Interface Lines: RES ET BUSY DIMMING BELL Industrial Electronic Engineers, Inc. Van Nuys, California 04/10/02 500 msec minimum 4 X 20 2 X 20...
  • Page 23: Timing Characteristics, Intel Mode

    DATA 80 nS MAX 10 nS DATA BUSY Industrial Electronic Engineers, Inc. Van Nuys, California 04/10/02 Read Timing 10nS MIN = high to read status = low to read data 0 uS MIN 120 nS MIN DATA VALID Write Timing 0 nS MIN 120 nS MIN DATA VALID...
  • Page 24: Timing Characteristics, Motorola Mode

    = high to read status = low to read data RD / WR DATA RD / WR DATA BUSY Industrial Electronic Engineers, Inc. Van Nuys, California 04/10/02 Read Timing 120 nS MIN 120 nS MIN 25 nS 25 nS 10 nS Rise Fall 0 nS...
  • Page 25: Timing Characteristics, Lcd Mode

    = high to read status = low to read data RD / WR DATA RD / WR DATA BUSY Industrial Electronic Engineers, Inc. Van Nuys, California 04/10/02 Read Timing 120 nS MIN 120 nS MIN 25 nS 25 nS 10 nS Rise Fall 0 nS...
  • Page 26: Programming Codes

    PROGRAMMING CODES The Century Series control codes occupy two hexadecimal address blocks. The first block is comprised of 00h–1Fh, while the second overlays part of the character table at 30h–3Fh. Control codes shown in Bold typeface are power–on defaults. Numeric Order Control Codes (RS) = Low for the following Control Codes] Code Name...
  • Page 27 Terminate Self–test Applies to 036X2–151–05240 & 036X2-160-05440 only. Unassigned for all other models. Applies to 036X2-121-11120 only. Unassigned for all other models. While unassigned Control Codes have no function, they are viewed as activity if received by the display and will cause the Screen Saver function to reset.
  • Page 28: Cursor Control Codes

    Cursor Control Codes (RS) = Low for the following Control Codes] Backspace Cursor Moves the cursor one position left. (Right if 3Ah is selected.) Functions only on current line, does not move cursor to previous line. Advance Cursor Moves the cursor one position right. (Left if 3Ah is selected.) If the cursor is in the last position on a line (other than the last line of the display screen), it will move to the first position of the next line.
  • Page 29 Cursor Control Codes (Cont.) (RS) = Low for the following Control Codes] Cursor Off Makes cursor invisible. Other cursor functions are not affected. Cursor On Makes cursor visible at 4 Hz blink rate. (Default) Applies to 036X2–151–05240 & 036X2-160-05440 only. Unassigned for all other models. Industrial Electronic Engineers, Inc.
  • Page 30: Data Display Mode Codes

    Data Display Mode Codes The following control codes define the way the display behaves after the last character has been written to the screen. (RS) = Low for the following Control Codes] Set Vertical Scroll Mode Causes data to scroll up one line, upon receipt of a displayable character, after the last character is written to the last line of the display screen.
  • Page 31: Prepare To Read Codes

    Prepare to Read Firmware Identification Number & Display Format Outputs a 19 byte string representing the firmware ID number and line/column format. e.g., IEE,35062–01,LXXCXX (for model: 036X2-100, -105, -122, -124, -130, -134) e.g., IEE,35440-01,LXXCXX (for model: 036X2-106, -116, -120, -121, -151) e.g., IEE,35973-01,L04C40 (for model: 036X2-160)
  • Page 32: Screen Control Codes

    Screen Control Codes (RS) = High for the following Control Codes] Set Display Screen or Column Brightness Level Sets the display brightness level using a 3 byte command consisting of control code 30h, column ID, and brightness level. Column ID code FFh sets all columns. Brightness levels range from 00h (brightest) through 07h (dimmest).
  • Page 33 Screen Control Codes (Cont.) (RS) = High for the following Control Codes] Erase Line Data With End Blink Erases 1 or more lines of data (with blink) using a 2 byte command consisting of control code 36h and blink field/line data. Bits 0 through 3 retain (0) or erase (1) lines 0 through 3 respectively.
  • Page 34: Miscellaneous Codes

    Miscellaneous Codes (RS) = Low for the following Control Codes] Null No operation. Sending a 00h to the display is viewed by software as activity, and will reset a Screen Saver code (3Ch). Bell/Alarm Output Activates 160 msec drive signal for alarm tone. Scroll Line Lock Sets 1 or more lines to be locked out from the Vertical Scroll function using a 2 byte command consisting of the control code 10h and a line ID.
  • Page 35 Miscellaneous Codes (Cont.) (RS) = High for the following Control Codes] Execute Self–test Displays the following data in sequence: 1. Software version number. S/W NUMBER : XXXXX–XX 2. Baud Rate selected. BAUD : NNNN 3. Interface Mode selected. INTERFACE: INTEL(MOTOROLA)[LCD] 4.
  • Page 36: Lcd Mode Control Codes (Without Interface Converter)

    LCD Mode Control Codes (Without Interface Converter) [See Figure 3–10 on Sheet 18 for personality jumper settings] RD/ WR Bit “B” is used to control character blinking on models which have an underbar cursor. Bit “C” is used to control the underbar cursor on models which support that style.
  • Page 37: Lcd Mode Control Codes (With Interface Converter)

    LCD Mode Control Codes (With Interface Converter) [See Figure 3–10 on Sheet 18 for personality jumper settings] RD/ WR Bit “B” is used to control character blinking on models which have an underbar cursor. Bit “C” is used to control the underbar cursor on models which support that style.
  • Page 38: Options And Accessories

    OPTIONS AND ACCESSORIES The following sections list commonly available options and accessories to the Century Series of Vacuum Fluorescent Displays which can enhance performance or utility for specific applications. Performance Options 0 = Standard Temperature Range 1 = Wide Temperature Range 2 = Standard Temperature Range (with Conformal Coating) 3 = Wide temperature Range...
  • Page 39: Outline Drawings

    OUTLINE DRAWINGS The following pages contain Outline Drawings of the available Century Series Dot Matrix Vacuum Fluorescent Displays. Each outline drawing includes: 1. Mounting and elevation dimensions to assist the user in packaging design. 2. Interface connector location, contact arrangement and keying. 3.
  • Page 40: Outline Drawing, 036X2-100-05420

    Figure 6–1 036X2–100–05420, 4X20 5mm SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 39 of 49 04/10/02...
  • Page 41: Outline Drawing, 036X2-105-05220

    Figure 6–2 036X2–105–05220, 2X20 5mm SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 40 of 49 04/10/02...
  • Page 42: Outline Drawing, 036X2-106-04240

    Figure 6–3 036X2–106–04240, 2X40 4.7mm SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 41 of 49 04/10/02...
  • Page 43: Outline Drawing, 036X2-121-11120

    Figure 6–4 036X2–120–09120, 1X20 9mm SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 42 of 49 04/10/02...
  • Page 44 Figure 6–5 036X2–121–11120, 1X20 11mm SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 43 of 49 04/10/02...
  • Page 45: Outline Drawing, 036X2-122-09220

    Figure 6–6 036X2–122–09220, 2X20 9mm SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 44 of 49 04/10/02...
  • Page 46: Outline Drawing, 036X2-124-09420

    Figure 6–7 036X2–124–09420, 4X20 9mm SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 45 of 49 04/10/02...
  • Page 47: Outline Drawing, 036X2-134-11420

    Figure 6–8 036X2–130–11220, 1X20 11mm SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 46 of 49 04/10/02...
  • Page 48 Figure 6–9 036X2–134–11420, 4X20 11mm SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 47 of 49 04/10/02...
  • Page 49: Outline Drawing, 036X2-151-05240

    Figure 6–10 036X2–151–05240, 2X40 5mm SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 48 of 49 04/10/02...
  • Page 50 Figure 6–11 036X2–160–05440, 4X40 5mm SIZE CODE IDENT NO. S036X2–XXX–XXXXX Industrial Electronic Engineers, Inc. 05464 Van Nuys, California SCALE SHEET 49 of 49 04/10/02...

Table of Contents