This document is the property of SATAM And may not be given to third party without prior authorization SATAM reserves to itself the right to alter this document without prior notice IN ACCORDANCE WITH the European Directive 94/9/CE - ATEX SATAM Siège Social : Paris Nord II –...
2. General The EMS and ZCE 18 metering units are designed to deliver hydrocarbon liquids at a kinematic viscosity of less than 20 mm2/s, industrial oils and fatty acid methyl esters for diesel motors, ethanol delivered by tanker or self-service area. This section sets out the necessary information for receipt, installation and implementation of the EMS &...
3.2. Components The EMS and ZCE 18 control delivery meters are made up of the following components: TOKHEIM SOFITAM APPLICATIONS FALAISE DISPOSITIF CALCULATEUR INDICATEUR ELECTRONIQUE Mod╔le : RUBIS N░ de d┼cision: 00.00.510.004.1 N░ s┼rie: Ann┼e 20 TOKHEIM SOFITAM APPLICATIONS Fr┼quence maxi: 1666 Hz 0081 II 2 G Temp┼rature de fonctionnement: -25░C ╚...
1 An air separator: a) For tankers: A SATAM FS 24 or EC 36-1 air separator filter including a protection filter in stainless steel (200µ for petrol and 450µ for diesel). b) For a fixed dispenser: An EC 27-40 type SATAM air separator for flows greater than 24 m /h and for underground storage tanks.
The entrance connection of the EMS and ZCE 18 counting unit is made behind the separator filter by a by a welded flange of Ø 2” (specifically provided by SATAM), for the EMS and ZCE 18 with a three way discharge valve, a female flange of 2” cylindrical gas for the hose and a threaded male flange connector of 2”...
15/07/09 8/11 U509001-e Revision : 01 SATAM Siège Social : Paris Nord II – Bât. Le Gauguin – 47, allée des Impressionnistes Usine de Falaise – Avenue de Verdun – B.P. 129 – 14700 FALAISE – France B.P. 85012 – Villepinte – 95931 Roissy C.D.G. Cedex - France Tél.
Important : Fixed Installations Whatever the type of pump, the motor must always be protected by a circuit breaker situated on the electricity board, set at the maximum level corresponding to the motor’s power. It is further recommended that the circuit breaker should include a thermal relay of minimum power, to avoid the machine starting up again unexpectedly after a short stop for that reason.
- A metrological check at the time of use is known as a ‘primitive’ check. - An annual metrological check is known as a ‘periodic’ check. (These operations are undertaken by appointed companies or by SATAM in the context of the MID directive)