Electrical Connection; Wire Connection - Fisher & Paykel MINIMAL CID364DTB4 Installation Manual

Downdraft induction cooktop
Hide thumbs Also See for MINIMAL CID364DTB4:
Table of Contents

Advertisement

CONNECTION LOCATION
Before connecting the cooktop to the mains power supply check that:
The domestic wiring system is suitable for the power drawn by the cooktop.
z
The voltage corresponds to the value given in the rating plate.
z
The power supply cable sections can withstand the load specified on the rating plate.
z
CONNECTION
MAX. CURRENT DRAW
3 Wire
32A
4 Wire
34A
connection location

ELECTRICAL CONNECTION

MAX. LOAD
VOLTAGE
7800W
120/240 V
7100W
120/208 V
rating plate location
BASE

3 WIRE CONNECTION

Using UL listed wire connectors, connect the 2 black wires together and the 2 red wires
z
together. Connect the green (or yellow-green) and white cooktop cables to the white
(neutral) wire in the junction box using the UL listed wire connectors
Install junction box cover.
z
Home power supply cable
Red wires
White wires
UL listed or CSA approved
conduit connector connector
4 WIRE CONNECTION
Using UL listed wire connectors, connect the 2 black wires together, the 2 red wires
z
together and the 2 white wires together. Connect the green (or yellow-green) ground wire
from the cooktop cable to the green (or yellow-green) ground wire in the junction box
using UL listed wire connectors.
Install junction box cover.
z
Home power supply cable
Black wires
Ground wires
UL listed wire connector
UL listed or CSA approved
conduit connector connector
Junction box
Black wires
UL listed wire connector
Cooktop 4 wire cable
Junction box
White wires
Red wires
Cooktop 4 wire cable