E9
Water circulation pump error
E7
Fan motor locked
F3
Discharged temperature error
H0
High water outlet error
FA
High pressure side error
H3
Pressure switch error
Note:
1. After a component is replaced or the inspection is completed, turn the breaker OFF for
a period of 3 minutes before restarting to confirm the error does not re-occur.
2. If the corrective actions above do not solve the error problem, a malfunction of the PCB
is highly likely.
Water Supply Quality (Supplemental)
Chloride and PH
In areas with a high concentration of chloride in the water, that water can cause
corrosion and subsequent failures. Where the chloride level exceeds 0.1 ounces per
gallons (200 mg/litre), the warranty is no longer valid on to the heat pump unit and tank
unit.
PH is a measure of whether the water is alkaline or acid. In an acidic water supply, the
- Check the water is full fill in the Tank.
- If the water circulation pump is not working,
replace the pump.
- Check the revolution of pump by controller.
If the revolution is low, replace the pump.
- Replace the main PCB
- Remove foreign objects around the fan motor.
- Check the fan motor connectors on the main
PCB.
- Replace the main PCB.
- Measure resistance of the discharged
thermistor.
- Replace the main PCB or heat pump.
- Check the water circuit is not flowing by air, dirt
or scaling.
- If the water circulation pump is not working,
replace the pump.
- Measure resistance of water outlet(outgoing)
thermistor.
- Replace the thermostat.
- Replace the main PCB.
- Check the heat pump piping for any blockage.
- Check for any piping bend, blockage or kink.
- Check if the pipes are frozen.
- Ensure mains water supply is available.
- Ensure all shut off valves are open.
- If the water circulation pump is not working,
replace the pump.
- In areas with hard water ensure Gas Cooler is
not scaled up, descale if necessary.
- Replace the main PCB or heat pump.
- Check the thermistor connectors on the main
PCB or control PCB in the heat pump unit for any
disconnect, fall-off, wire breakage or short circuit.
- Replace the main PCB.
SANCO
Heat Pump – Installation Manual
2
Page 28 of 44

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SANCO2 GS4-45HPC and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Sanco2 san-43ssaqaSanco2 san-83ssaqaSanco2 san-119glbk

Table of Contents

Save PDF