ECO2 Systems SANCO2 GS4-45HPC Installation Manual page 27

Heat pump water heater with natural refrigerant
Hide thumbs Also See for SANCO2 GS4-45HPC:
Table of Contents

Advertisement

H6
Compressor revolution error
U0
Refrigerant leakage error
Main PCB error
E1
E2
Control PCB error
L7
Communication error between
F5
main PCB to control PCB
E8
High inlet current error
H8
Current error
L4
High temperature of module error
L5
High outlet current error
P4
Module temperature thermistor error
U2
High voltage error
HJ
Water circuit error
EC
High water outlet error
- Check the supply voltage.
- Measure resistance of each thermistors.
- Measure resistance of coil of expansion valve
to check open or short circuit.
- Replace the PCB or heat pump.
- Measure resistance of each thermistors.
- Measure resistance of coil of expansion valve
to check open or short circuit.
- Replace the main PCB or heat pump.
- Replace the main PCB.
- Replace the control PCB.
- Check the communication connector on the
main PCB and control PCB.
- Replace the main PCB or control PCB.
- Check the installation location.
- Check the supply voltage.
- Replace the main PCB or heat pump.
- Replace the main PCB.
- Check the installation location.
- Remove foreign objects from the evaporator
coil (e.g. fallen leaves, grass, snow)
- Check the Fan motor is not flowing by dirt.
- Replace the main PCB or fan motor.
- Measure resistance of the discharged
thermistor.
- Measure resistance of coil of expansion valve
to check open or short circuit.
- Replace the main PCB or heat pump.
- Replace the main PCB.
- Check the supply voltage.
- Check the inlet water valve.
- Check for any piping bend, blocking, kink or
frozen.
- Measure resistance of each Thermistor.
- Measure resistance of coil of expansion valve
to check open or short circuit.
- Replace the main PCB or heat pump.
- Check the water circuit is not flowing by air, dirt
or scaling.
- If the water circulation pump is not working,
replace the pump.
- Measure resistance of water outlet(outgoing)
thermistor.
- Replace the main PCB.
Sanden Heat Pump – Installation Manual
SANCO
Heat Pump – Installation Manual
Page 19 of 32
2
Page 27 of 44

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SANCO2 GS4-45HPC and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Sanco2 san-43ssaqaSanco2 san-83ssaqaSanco2 san-119glbk

Table of Contents

Save PDF