Item Part #
Description
F
A
T
AN
SSEMBLIES AND
HERMOSTATS
,
8 Ft, 10 Ft, 12 Ft
14 Ft & 16 Ft
A. 12W Standard Fan Assembly
0047000
Fan Motor, Evaporator
(MO.4410103)
0142780
Fan Blade (FB.0142780)
embossing toward motor
12W Energy Efficient Fan Assembly
0477655
Fan Motor, Evaporator
(MO.4410546)
0142780
Fan Blade (FB.0142780)
B. Optional Adjustable Refrigeration Thermostat (2)
0448347
(CT.4481631)
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
B
A
Wiring Item #
®
E
Item Part #
H
EATERS
C.
0487118
(1)
L
B
AMPS AND
ALLASTS
D. Ballast, Electronic
0355398
0355716
(1)
0447740
E.
Technical Data Sheet
P/N 0492435_A
NSF
®
Certified
April 2007
C
E
Serial Plate
Description
Wiring Item #
Anti-Sweat Heater
(HE.4850668)
(BA.4480118)
(BA.0355716)
(BA.4481278)
Fluorescent Lamp
Replace with like fixtures
P/N 0492435_A
SI2
(3)
(4)
(5)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SI2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hussmann SI2

  • Page 1 0142780 Fan Blade (FB.0142780) B. Optional Adjustable Refrigeration Thermostat (2) 0448347 (CT.4481631) ©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM ® Wiring Item # Item Part # EATERS 0487118 AMPS AND D.
  • Page 2 Schedule 40 PVC drip pipe Refrigeration Outlet LH end of case to center of refrigeration outlet RH end of case to center of refrigeration outlet 2 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Electrical Service Refrigeration & Coil Stubout Drains...
  • Page 3: Load Limit Profile

    Air flow between the shelves, from the CAD to the return, must be maintained at all times for optimum operating efficiency and to prolong product shelf life. At no time should merchandisers be stocked beyond the load limits indicated. P/N 0492435_A HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM (460) 7/8 (225) (152)
  • Page 4: Electrical Data

    115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 4 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 8 ft 10 ft 12 ft...
  • Page 5 All components must have mechanical ground, and the merchandiser must be grounded. R = Red Y = Yellow G = Green BL = Blue B = Black W = White = 120V P OWER P/N 0492435_A HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM Anti-sweat Heaters WARNING IRCLED NUMBERS ARTS...
  • Page 6 R = Red = 120V P = 120V N OWER 6 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. RANGE OR WARNING Circled Numbers = Parts List Item Numbers G = Green BL = Blue B = Black W = White...