Hussmann SI1 Technical Data Sheet
Hussmann SI1 Technical Data Sheet

Hussmann SI1 Technical Data Sheet

Single deck island

Advertisement

D
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Item Part #
Description
F
A
T
AN
SSEMBLIES AND
HERMOSTATS
,
8 Ft, 10 Ft, 12 Ft
14 Ft & 16 Ft
A. 12W Standard Fan Assembly
0047000
Fan Motor, Evaporator
(MO.4410103)
0407532
Fan Blade (FB.4780619)
embossing toward motor
12W Energy Efficient Fan Assembly
0477655
Fan Motor, Evaporator
(MO.4410546)
0407532
Fan Blade (FB.4780619)
B. Optional Adjustable Refrigeration Thermostat (2)
0448347
(CT.4481631)
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
B
A
Wiring Item #
®
E
Item Part #
H
EATERS
C.
0447688
(1)
L
B
AMPS AND
ALLASTS
D. Ballast, Electronic
0447683
(1)
E.
Technical Data Sheet
P/N 0492443_A
NSF
®
Certified
April 2007
C
Serial Plate
Description
Wiring Item #
Anti-Sweat Heater
(HE.4850682)
(BA.4440811)
Fluorescent Lamp
Replace with like fixtures
P/N 0492443_A
SI1
(3)
(4)
(5)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SI1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hussmann SI1

  • Page 1 0407532 Fan Blade (FB.4780619) B. Optional Adjustable Refrigeration Thermostat (2) 0448347 (CT.4481631) ©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM ® Wiring Item # Item Part # EATERS 0447688 AMPS AND D.
  • Page 2 Schedule 40 PVC drip pipe Refrigeration Outlet LH end of case to center of refrigeration outlet RH end of case to center of refrigeration outlet 2 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Electrical Service Refrigeration & Coil Stubout Drains...
  • Page 3: Load Limit Profile

    Air flow between the shelves, from the CAD to the return, must be maintained at all times for optimum operating efficiency and to prolong product shelf life. At no time should merchandisers be stocked beyond the load limits indicated. P/N 0492443_A HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM (346) (102) (260)
  • Page 4: Electrical Data

    115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 4 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 8 ft 10 ft 12 ft...
  • Page 5 All components must have mechanical ground, and the merchandiser must be grounded. R = Red Y = Yellow G = Green BL = Blue B = Black W = White = 120V P OWER P/N 0492443_A HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM Anti-sweat Heaters WARNING IRCLED NUMBERS ARTS...
  • Page 6 G = Green BL = Blue B = Black W = White = 120V P = 120V N = Field G = Case G OWER EUTRAL ROUND ROUND 6 of 6 SI1 Technical Data Sheet HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Table of Contents