Chapter 6
Hardware Diagnostic Tests
You can also view POST error codes with the show diagnostic post command. This command displays
the results of each POST that executes at power-up.
SFS-7000P# show diagnostic post
======================================================================
======================================================================
fru-slot
--------------------------------------------------------------------------------
card(1)
fan(1)
fan(2)
power-supply(1) passed
Display FRU errors on your switch by entering the show diagnostic fru-error command.
Step 2
SFS-7000P# show diagnostic fru-error
======================================================================
======================================================================
fru-slot
--------------------------------------------------------------------------------
card(1)
fan(1)
fan(2)
power-supply(1) none
Table 6-1
Table 6-1
Error Number
1
2
3
OL-10853-01
post-status
failed
passed
passed
fru-error
_FRU_POWER_CONTROLLER_CONFIG_ERR
none
none
lists the hardware errors that are logged for the power supply.
Cisco SFS 7000P and SFS 7000D Server Switches Power Supply Errors
Description
Power supply DC fail error
Power supply fan fail error
Power supply I2C communication error
Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide
Post Status
error-codes
1:0:0:0
0:0:0:0
0:0:0:0
0:0:0:0
Fru-Error
Displaying Hardware Errors
6-9