Chapter 6
Hardware Diagnostic Tests
Figure 6-1
P o w e r S u p p
Enter the show diagnostic fan command.
SFS-7000P# show diagnostic fan
======================================================================
======================================================================
Total=1
Enter the diag fan id command.
Step 2
SFS-7000P# config
SFS-7000P(config)# diag fan 1
SFS-7000P(config-diag-fan-1)# test self-test
SFS-7000P(config-diag-fan-1)# start
SFS-7000P(config-diag-fan-1)# exit
SFS-7000P(config)# exit
SFS-7000P# show diag fan
======================================================================
======================================================================
SFS-7000P#
Display the progress of the test by entering the show diag fan command.
Step 3
SFS-7000P(config-diag-fan-1)# exit
SFS-7000P(config)# exit
OL-10853-01
Power Supply Numbers on the Cisco SFS 7000P and SFS 7000D Server Switches
ly
1
module-type : fan
module-number : 2
test : self-test
iterations : 1
action : start
result : success
percentage-completed : 100
result-string : Fan Self Test Completed, Final report : Passed=1, Failed=0,
module-type : fan
module-number : 1
test : self-test
iterations : 1
action : start
result : in-progress
percentage-completed : 70
result-string : Self Test, Current report : In progress...
Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide
P o w e r S u p p
ly
2
Diagnostic Tests For Fan
Diagnostic Tests For Fan
About Diagnostic Tests
6-5