Controls And Adjustments; A) Default Dip Switch Settings; B) Harvest Timer (S4 Dip Switch 1 & ) - Hoshizaki KMS-1230MLH Service Manual

Modular crescent cuber serenity series
Hide thumbs Also See for KMS-1230MLH:
Table of Contents

Advertisement

3. Controls and Adjustments

a) Default Dip Switch Settings

The dip switches are factory-adjusted to the following positions:
Dip Switch No.
1
KMS-130MLH ON OFF OFF ON
S5 Dip Switch (Do Not Adjust)
Dip Switch No.
1
KMS-130MLH OFF ON OFF OFF OFF
S4 Dip Switch
b) Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts counting when the thermistor reads 48°F (9°C) at the evaporator
outlet. No adjustment is required under normal use, as the harvest timer is adjusted to
the suitable position. Before changing this setting, call the HOSHIZAKI Technical Support
Department at 1-800-33-1940 for recommendations. Keep in mind that setting the
harvest timer to a longer setting will decrease 4 hour production.
S4 Dip Switch

3
4
5
6
ON
ON

3
4
5
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & )
Dip Switch Setting
No. 1
No. 
OFF
ON
OFF
ON
7
8
9
10
ON OFF OFF ON
Freeze Timer (9 & 10)
Normally in the OFF position (8)
Do not adjust (7)
Time
(seconds)
OFF
60
OFF
90
ON
10
ON
180
18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk-13hSrk-13h3

Table of Contents