I. Startup
1. Electrical power must be on at the condensing unit for a minimum of 4 hours
prior to start up to prevent compressor damage.
. All parts are factory-adjusted. Improper adjustments may result in failure.
3. If the unit is turned off, wait for at least 3 minutes before restarting the icemaker
to prevent damage to the compressor.
4. Do not operate the unit in the "WASH" position without water in the water tank.
This may cause damage to the water pump seal.
1) Open the water supply line shut-off valve.
) Remove the front panel.
3) Move the control switch on the control box to the "ICE" position.
4) Replace the front panel in its correct position.
5) Turn on the power supply, and allow the water tank to fill with water and the icemaker to
operate for a total of 10 minutes.
6) Turn off the power supply, and drain the water tank by removing the front panel, front
insulation panel, front frame and suction hose. See Fig. 10.
7) Replace the removed parts in their correct positions.
8) Remove all ice from the dispenser or storage bin and clean the dispenser or storage
bin.
9) Turn on the power supply to start the automatic icemaking process.
IMPORTANT
Suction Hose
Front Frame
Thumbscrew
Fig. 10