Fastening the cooktop to the bench
This cooktop is suppled with fastening brackets (and screws) that will cope with a
bench thickness of 20-50mm. For benches thicker than 50mm, recess the underside
to a thickness of 20-50mm.
Connecting the cooktop to the gas supply
IMPORTANT!
This cooktop is supplied factory-set for either Natural Gas or ULPG.
●
Please ensure that the factory-set adjustment of the cooktop is compatible with the
local distribution conditions (nature of gas and pressure).
The gas connection must be carried out by a suitably qualified person according to
●
the relevant standards.
For Natural Gas, connect the gas supply to the gas pressure regulator supplied with the
●
cooktop. Adjust the regulator to obtain a test point pressure of 1 kPa (4"W.C.) with the
three largest burners operating at the highest setting.
For ULPG, connect the the gas supply to the test point adaptor supplied with the
●
cooktop. Ensure that the supply pressure is regulated to 2.75 kPa (11" W.C.)
Make sure the connection point will be accessible with the cooktop installed.
●
To enable the gas supply to be readily shut off, make sure the connection is fitted with
●
an isolating valve close to the cooktop.
Attach the duplicate appliance data label on a surface adjacent to the cooktop, so that
●
it will be easily read with the cooktop installed.
For instructions on converting the cooktop for use with a different gas type, see section
●
'Converting to a different gas type'.
Gas connection to these cooktops MUST use the elbow supplied. The regulator will not
●
seal if installed without it.
Ensure the fibre washer (supplied) is located between the elbow (supplied) and
●
cooktop gas inlet. Failure to use this washer will cause the connection to leak. Tighten
the floating nut to firm finger tight, plus an additional 1/4 turn (90
INSTALLATION INSTRUCTIONS
50mm
20mm
recessed to
50mm
Fastening the cooktop to the bench
o
).
9