3) Attach a compressed air or carbon dioxide supply to the condenser water supply line
drain valve.
4) Open the water regulating valve by using a screwdriver to pry up on the spring retainer
underneath the spring. While holding the valve open, blow out the condenser using the
compressed air or carbon dioxide supply until water stops coming out.
5) Close the condenser water supply line drain valve.
6) Replace the panels in their correct positions.