Electrical Connection - Hoshizaki DCM-750BAH Instruction Manual

Cubelet icemaker / dispenser
Hide thumbs Also See for DCM-750BAH:
Table of Contents

Advertisement

E. Electrical Connection
1. Electrical connections must be made in accordance with the instructions on
the "WARNING" tag, provided with the pig tail leads in the junction box.
. Electrical connections must meet national, state, and local electrical code
requirements. Failure to meet these code requirements could cause severe
injury to individuals or extensive damage to equipment.
3. Be sure to install a proper ground to the icemaker.
• Electrical connections must be installed in accordance with applicable national, state, and
local regulations.
• Usually an electrical permit and services of a licensed electrician are required.
• The icemaker requires an independent power supply. See the nameplate for proper
voltage and breaker/fuse size.
• The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• The white lead must be connected to the neutral conductor of the power source. Miswiring
results in severe damage to the icemaker. See Fig. .
• The opening for the power supply connection is 7/8" DIA to fit a 1/" trade size conduit.
WARNING
Fig. 2
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcm-750bah-osDcm-750bwhDcm-750bwh-os

Table of Contents