2. LOCATION
1. This ice dispenser is not intended for
outdoor use. Normal operating ambient
temperature should be within +5°C to
+40°C. Normal operating water tempera-
ture should be within +5°C to +35°C.
Operation of the ice dispenser, for ex-
tended periods, outside of these normal
temperature ranges may affect production
capacity.
2. The ice dispenser should not be located
next to ovens, grills or other high heat
producing equipment.
3. The location should provide a firm and
level foundation for the equipment at
normal counter top height.
4. Allow 15 cm. clearance at rear, sides and
top for proper air circulation and ease of
maintenance and/or service should they
be required.
5. This appliance is not suitable for installa-
tion in an area where a water jet could be
used and where dripping is not allowed.
6. Do not place anything on top of the ice
dispenser or in front of the Louver.

3. INSTALLATION

• Incorrect installation can cause harm to people,
animals or things, for which the manufacturer
cannot be held responsible.
1) Position the ice dispenser in the selected perma-
nent site.
2) Level the ice dispenser in both the left-to-right and
front-to-rear directions.
3) Attach the two support brackets to the lower rear
of the dispenser (one each side).
4) Attach the brackets to the counter surface using 4
suitable screws (not supplied).
Note: The brackets are to ensure the dispenser
cannot be tilted or moved during use.
91A2FB10A9907
IMPORTANT

4. ELECTRICAL CONNECTIONS

WARNING
THIS APPLIANCE MUST BE EARTHED
This ice dispenser requires an earth that meets
the national and local electrical code require-
ments. To prevent possible severe electrical
shock to individuals or extensive damage to
equipment, install a proper earth wire to the ice
dispenser. Remove the plug from the mains
socket before any maintenance, repairs or
cleaning is undertaken.
• This ice dispenser must have a separate power
supply or receptacle of proper capacity. See the
Nameplate.
• The main control box fuses are rated at 10A, 1A
and 0.5A and should only be replaced by a
qualified service engineer.
• Usually an electrical permit and services of a
licensed electrician are required.
• If the supply cord and the plug should need to be
replaced, it should only be done by a qualified
service engineer.
DCM-200F-GE Voltage Selection
The Voltage Selection
Switch is located inside
near the connection wires
for the machine. Select
the proper voltage
BEFORE connecting
power to the machine.
Use the following chart
for the correct voltage
selection.
3
ENGLISH