IBM Elastic Storage System 3200 Service Manual page 34

Hide thumbs Also See for Elastic Storage System 3200:
Table of Contents

Advertisement

# mmvdisk nodeclass list
Verify the new 24 NVMe disk topology on both canisters by issuing the following command:
# mmvdisk server list --disk-topology --node-class <node class name>
Example
The following example is a case of a missing drive.
# mmvdisk server list --disk-topology --node-class ess3200_x86_64_mmvdisk_78E400K
node
number
server
------
--------------------------------
6
ess3200rw3a-hs.gpfs.ess
7
ess3200rw3b-hs.gpfs.ess
To identify what needs attention, use the following commands:
mmvdisk server list -N ess3200rw3a-hs.gpfs.ess --disk-topology -L
mmvdisk server list -N ess3200rw3b-hs.gpfs.ess --disk-topology -L
Example
# mmvdisk server list -N ess3200rw3a-hs.gpfs.ess --disk-topology -L
GNR server: name ess3200rw3a-hs.gpfs.ess arch x86_64 model ESS3200-5141-FN1 serial 78E400KA
GNR enclosures found: 78E400K
Enclosure 78E400K (IBM-ESS 5141-FN1, number 1):
Enclosure 78E400K expander sg0[E113]
Enclosure 78E400K expander sg0 23 disks diskset "00751"
Enclosure 78E400K sees 23 disks (23 SSDs, 0 HDDs)
GNR server disk topology: ESS 3200 FN1 24 NVMe (match: 95/100)
GNR configuration: 1 enclosure, 23 SSDs, 1 empty slot, 23 disks total, 0 NVRAM partitions
Location 78E400K-7 appears empty but should have an SSD
To rectify the error, reseat the drive in that slot and rerun the command:
# mmvdisk server list --disk-topology --node-class ess3200_x86_64_mmvdisk_78E400K
node
number
server
------
--------------------------------
6
ess3200rw3a-hs.gpfs.ess
7
ess3200rw3b-hs.gpfs.ess
• Both canisters must show a 24 NVMe disk topology.
• If any errors such as a new disk is bad or does not show up are reported, the errors must be fixed
before proceeding.
7. To check whether all 24 NVMe drives have the current firmware version, issue the following
command from one of the canisters. For more information about the current firmware version, see
the Drives section in IBM Elastic Storage System documentation.
Note: For FCM drives, the minimum drive firmware level is 2.1.7 (2_1_7).
# mmlsfirmware --type <component type>
Example
# mmlsfirmware --type drive
type
product id
----
----------
drive
a8241014065c
Enclosure 5141-FN1-78E400K Drive 10
drive
a8241014065c
Enclosure 5141-FN1-78E400K Drive 11
drive
a8241014065c
Enclosure 5141-FN1-78E400K Drive 12
22 IBM Elastic Storage System 3200: Service Guide
enclosure
firmware
serial number
-------------
--------
78E400K
SN5ASN5A
78E400K
SN5ASN5A
78E400K
SN5ASN5A
needs
matching
attention
metric
---------
--------
yes
95/100
yes
95/100
needs
matching
attention
metric
---------
--------
no
100/100
no
100/100
available
level
firmware
location
--------
--------
SN5ASN5A
ess3200rw3a-hs Rack Bodhi-Rack-1520 U25-26,
SN5ASN5A
ess3200rw3a-hs Rack Bodhi-Rack-1520 U25-26,
SN5ASN5A
ess3200rw3a-hs Rack Bodhi-Rack-1520 U25-26,
disk topology
-------------
ESS 3200 FN1 24 NVMe
ESS 3200 FN1 24 NVMe
disk topology
-------------
ESS 3200 FN1 24 NVMe
ESS 3200 FN1 24 NVMe

Advertisement

Table of Contents
loading

Table of Contents