Burner and nozzle specifications

Table 1
Burner
Reduced Rapid (RR)
Semi Rapid (S)
Auxiliary (A)
Triple Crown (TC)
Total Thermal Power
(MJ/h)
Supply pressures
* At 15°C and 101,3 kPa dry gas
Propane
= 95,8 MJ/m³
Natural gas = 37,8 MJ/m³
A
RR
TC
S
PH640MT NG
PH640MST NG
PH640MT PR
PH640MST PR
Diameter
Nominal Thermal
(mm)
100
75
55
130
Nominal (kPa)
Minimum (kPa)
Maximum (kPa)
Propane
Nozzle
Power
1/100
(MJ/h)*
(mm)
9,0
80
5,5
64
3,5
50
15,0
105
33,0
2,75
2,00
3,50
Natural Gas
Nominal
Nozzle
Thermal Power
1/100
(MJ/h)*
(mm)
8,3
129
6,0
110
3,3
80
15,0
175
32,6
1,00
0,75
1,20