Comtech EF Data UT-4518E-1 Installation And Operation Manual page 88

Up converter
Table of Contents

Advertisement

UT4500 Series Up Converter
Remote Control
B.6.4.8 P
M
ACKED
Packed Maintenance Status: <DEV/PACRMS_'cr'
Confirmation:
where:
B.6.4.9 P
U
ACKED
Packed Utility Status:
Confirmation:
where:
S
AINTENANCE
TATUS
>DEV/PACRMS_aabbccddeeeffgghhii'cr''lf']
aa = V15 scaled 123mV per count (0x00 - 0xFF)
bb = V14 scaled 123mV per count (0x00 - 0xFF)
bc = VCC scaled 39mV per count (0x00 - 0xFF)
dd = V5D scaled 39mV per count (0x00 - 0xFF)
eee = signed Temperature in degrees C (-10 to +60)
ff = IFLO tune scaled 67mV per count (0x00 - 0xFF)
gg = SUM tune scaled 54mV per count (0x00 - 0xFF)
hh = COARSE tune scaled 78mV per count(0x00 - 0xFF)
ii = FINE tune scaled 89mV per count (0x00 - 0xFF)
S
TILITY
TATUS
<DEV/PACRUS_'cr'
>DEV/PACRUS_abbcdeeffghhii'cr''lf']
a = 0=EIA-232, 1=EIA-485
bb = Address in hex (01 to FF)
c = 0 if Baud Rate 38400
= 1 if Baud rate 19200
= 2 if Baud rate 9600
= 3 if Baud rate 480
= 4 if Baud rate 2400
= 5 if Baud rate 1200
d = 0 if Data Format 8-N-1
= 1 if Data Format 7-E-2
= 2 if Data Format 7-O-2
ee = Osc. Adjust in hex (00 to FF)
ff = Slope Adjust times by 10 (00 to 10)
g = Always 0, unused
hh = LCD Contrast (0 to 30)
ii = LCD Brightness (0 to 30)
72
MN/UT4500.IOM
Rev. 0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ut-4500 seriesUt-4518-1

Table of Contents