Comtech EF Data UT-4518E-1 Installation And Operation Manual page 28

Up converter
Table of Contents

Advertisement

UT4500 Series Up Converter
Introduction
Characteristic
Phase Noise
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
Indicators
Power On
Mute
Remote
Reference
Stored Fault
Fault
Test Points
RF Sample
IF Sample
Power
Voltage
Frequency
Dissipation
Environment
Temperature
Altitude
Humidity
Physical
Width
Height
Depth
Weight
Options
- 1
- 2
Summary Alarm
Relay Closure
Specification
LIMIT
-66 dBc/Hz
-69 dBc/Hz
-76 dBc/Hz
-79 dBc/Hz
-86 dBc/Hz
-89 dBc/Hz
-96 dBc/Hz
-99 dBc/Hz
-106 dBc/Hz
-109 dBc/Hz
Green LED
Yellow LED
Yellow LED
Yellow LED
Red LED
Red LED
SMA, -20 dBc Nominal
BNC, -20 dBc Nominal
90-250 Vac Autoranging
47-63 Hz
60 Watts
0-50° C
10,000 Feet MSL
0-95 % Relative
19 Inches (48.30 cm)
1.75 Inches (4.45 cm)
22 Inches (55.90 cm)
15 Pounds (7.00 kg)
IO Module
RF/IF Switch
Form C
12
MN/UT4500.IOM
TYPICAL
REV. 0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ut-4500 seriesUt-4518-1

Table of Contents