Maintenance

Cleaning and replacing the air filter

Please check and clean the air filter periodically. When the indicators or a
message prompts you to clean the air filter, comply with it as soon as possible.
Replace the air filter when it is damaged or too soiled. To prepare a new air filter,
contact to your dealer and tell the air filter type number.
Type number : MU04951
When you replace the lamp, please replace the air filter. An air filter of specified
type will come together with a replacement lamp for this projector.
1.
Turn the projector off, and unplug the power cord.
Allow the projector to sufficiently cool down.
2.
Use a vacuum cleaner on and around the filter cover.
3.
Pull the filter cover knobs while lifting it. The filter unit
which consists of the filter' cover, air filter and filter
frame will come off.
4.
Use a vacuum cleaner for the filter vent of the
projector and the filter frame side of the filter unit.
If the air filter is damaged or too soiled, replace it
according to the following procedure number 5 to 7.
Otherwise, please jump to the procedure number 8.
5.
Pull the filter frame's knob up while holding the filter
cover. The filter frame will come off and the air filter
will appear.
6.
Replace the air filter with new one.
7.
Put the filter frame back.
8.
Put the filter unit back into the projector.
(continued on next page)