Saeco Service Center-Quick Start Guide - Philips Saeco Moltio Service Manual

Table of Contents

Advertisement

MOLTIO
5.2.
Error codes
ERROR
CODES
The coffee grinder is blocked (grinder blades jammed or sensor not
01
reading properly)
The brewing unit is blocked in work position (microswitch not released
03
in up position after 3", torque error trying to move down, descent time
out exceeded)
The brewing unit is blocked in home position (microswitch not released
04
in down position after 3", torque error trying to move up, ascent time
out exceeded)
Water circuit / flow meter problems (water circuit blocked or no flow
05
meter signal)
Boiler temperature sensor short circuited
10
11
Boiler temperature sensor open circuit
The boiler temperature has exceeded the maximum allowed value
14
(165°c)
The boiler temperature has not increased by x°C in y sec (boiler power
15
supply disconnected, incorrect boiler fitted must be a 1300W boiler, par-
tial power supply to boiler, cut out thermostat tripped)
19
Mains voltage trouble
5.3. Saeco Service Center - Quick Start Guide
Saeco Service Center (SSC) is a tool with which you can re-program the machine and check the
diagnostic of the same.
You can download the software from the following link:
In support of this tool it is essential to order the Saeco Programming Device:
Cod. 20000490 "KIT PROGRAMMER SERKIT SSC2".
This kit includes the programmer and cables helpful.
All details related to the registration and operation are explained in the enclosed Quick start guide
(QSG).
Press the icon to view the document
To open the attached document is necessary to save the service manual on your PC.
DESCRIPTION
Saeco Service Center – Quick Start Guide
http://logsave.logtronics.com/SSC2/publish.htm
05 SERVICE MODE
13/13