GJD GEM Manual

GJD GEM Manual

Curtain pir detector

Advertisement

Quick Links

GEM
GJD150 Curtain PIR Detector
IP65, Suitable
for outdoor use
Detection range
selectable
3m - 12m

PACKAGE CONTENTS

1 x GEM body
1 x T-bracket assembly
4 x wall plugs
4 x wall fixing screws
1 x drilling template
1 x opening tool

INTRODUCTION

The GEM detector is an outdoor motion detector utilising
precise PIR technology.
The detector has two N/C outputs for alarm and tamper
triggering.

QUICK INSTALLATION

1.
Mount the detector following the instructions in
sections "Mounting the Unit" and "Detector Placement
and Beam Pattern".
2.
Power the unit and ensure switch 1 is set to ON. The
unit will flash for two minutes during this time. Fit the
front cover on the unit and when the unit has finished
flashing it will be ready for walk testing.

MOUNTING THE UNIT

During installation, protect the electronics against water as
trapped moisture can affect or damage the unit.
BASIC INSTALLATION, BEAM OUTWARD FROM
SURFACE (see figures 2,3,11,13)
1.
Use drilling template to locate the two mounting holes
(A figure 2).
2.
Next feed the cable through rear or side knock-outs
and then fix to the wall (B & C figure 2).
INSTALLATION WITH T-BRACKET ASSEMBLY, BEAM
ACROSS SURFACE (see figures 4,5,12,14)
1.
Use drilling template to locate the four mounting
holes (A figure 4).
2.
Next feed the cable through rear or side knock-outs (
B figure 4) and out through cable access point. Fix to
the wall and then secure the blanking plate onto the
unused side of the T-bracket (figure 5,15).
Front and rear
tamper detection
Temperature
compensation for
extreme environments

FRONT ASSEMBLY (see figure 6-10)

1.
Feed cable through grommet. Clip middle section
shown into lower part of back section (figure 8) push
back until flat to wall. Cut and wire the cable into the
terminal blocks (figure 6,7)
2.
Push the bottom of the front cover into clip on the
middle section and rotate back flat to the wall (figure
8). Secure by tightening the screw in access hole.
Finally push fit screw cover.
3.
To access the unit once installed first lever off the
screw cover (see figure 9). Unscrew the screw in the
access hole. Next reverse steps shown in (figure 8)
or to remove from the wall use provided clip to lever
off the wall mounting (see figure 10).
DETECTOR PLACEMENT AND BEAM PATTERN (see
figure 12 -15)
The detector uses infrared sensing to determine motion
detection. The optimum position of the detector should be
chosen to detect an intruder crossing the beam pattern
(figure 13), and to avoid traffic from roads and paths (figure
14).
For applications where the T-bracket is used ensure the
angle of the detector is pointing 2° away from the building
(figure 15).
The detector should be at an optimum height of 2-2.5m.
Secure the detector to a wall or solid fixture.

PROGRAMMING

The detector can be programmed with different range
and sensitivity options and also LED indication. This can
be done by changing the four DIP switch settings on the
detector PCB (see figure 6). The range can be set to 3, 6, 9
or 12m and the sensitivity can be changed to high or low.

WALK TEST

Set the LED Indication to Enabled (figure 6). On power up
the LED will flash red for 1 minutes. The detector will then
indicate an alarm condition with a red LED.
The alarm detection will flash red for 1s with an interval of
5s between detections when LED indication is ON.
Detect. Illuminate. Deter

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GEM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GJD GEM

  • Page 1 INTRODUCTION (figure 13), and to avoid traffic from roads and paths (figure The GEM detector is an outdoor motion detector utilising 14). precise PIR technology. For applications where the T-bracket is used ensure the The detector has two N/C outputs for alarm and tamper angle of the detector is pointing 2°...
  • Page 2 SPECIFICATIONS Part Number GJD150 Detection selectable 3m 6m 9m 12m range Normally Closed 50mA 24Vdc Alarm time 10s Alarm Normally Closed with 20Ω impedance 50mA Tamper Power input 12V +/- 3V @ max 20mA *During installation the DC supply fault current shall be limited to a maximum of 1A Operating -20°C to +55°C...
  • Page 4 RANGE 3 metres 6 metres 9 metres 12 metres SENSITIVITY High Sensitivity Sensitivity LED INDICATION Detector Disabled Enabled Side View Top View...
  • Page 5 Side View Top View...
  • Page 6 ENGINEER NOTES w: www.gjd.co.uk t: +44 (0) 1706 363 998 f: +44 (0) 1706 363 991 Unit 2, Birch Business Park, Whittle Lane, Heywood, Greater Manchester, OL10 2SX, UK...

This manual is also suitable for:

Gjd150Gjd150w

Table of Contents