Care and Cleaning

The thermometer should be cleaned between uses. Use an alcohol swab or a cotton
swab moistened with alcohol (70% Isopropyl) to wipe the thermometer casing and
measuring probe for 90 seconds. Wait 10 minutes, allowing the thermometer to
air-dry, before taking a measurement. Ensure that no liquid enters the interior of
the thermometer. NEVER use abrasive cleaning agents, thinners, or benzene for
cleaning, and NEVER immerse the thermometer in water or other cleaning liquids.
NEVER insert a sharp object into the scanner area or any other open
surface on the thermometer.

Warranty

You should first read all Instructions before attempting to use this product.
This product has been produced with the greatest care for normal, household use.
Following directions carefully will ensure dependable operation. If for any reason
(other than misuse or normal battery operation) you are dissatisfied with your Vicks
Non-Contact Forehead Thermometer, we will repair or replace it, at our option, at
no charge during the 2 year warranty period. Modification to the product by the
consumer is not authorised and voids the warranty.
If the thermometer does not function properly, first check the battery. Replace if
necessary. Batteries and packaging are excluded from the warranty.
If you experience unsatisfactory operation, please contact Felton Grimwade &
Bosisto's. If repair is required under the warranty period, the product should be
returned with proof of purchase to Felton Grimwade & Bosisto's service centre.
The purchaser assumes responsibility for the proper care and use of the product in
accordance with the printed operating manual. The purchaser or user must make
his or her judgment as to when to use the product and the length of use. Keep the
operation manual available as it is your guide to safe, efficient operation.
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure and
for compensation for any other reasonably foreseeable loss or damage. You are also
entitled to have the goods repaired or replaced if the goods fail to be of acceptable
quality and the failure does not amount to a major failure.
10

Product Specifications

Type:
Measuring range:
Resolution:
Laboratory Accuracy:
This thermometer displays a calculated oral equivalent estimate.
Display:
Acoustic:
Operating temperature:
Automatic Switch-off :
Weight:
Long term storage ranges
Storage/transport temperature:
Humidity:
Battery:
Pressure:
This infrared thermometer meets requirements established in ASTM Standard E
1965-98 (for the thermometer system). Full responsibility for the conformance of
the product to the standard is assumed by Kaz, USA, Inc., a Helen of Troy Company,
Health & Home, 400 Donald Lynch Blvd., Suite 300, Marlborough, MA 01752.
ASTM laboratory accuracy requirements for the thermometer only in the display
range of 36 °C to 39°C (96.8 °F to 102.2 °F) for infrared thermometers is ±0.3
°C (±0.5 °F), whereas for mercury-in-glass and electronic thermometers, the
requirement per ASTM Standards E 667-86 and E 1112-86 is ±0.1 °C (±0.2 °F).
Non-Contact Forehead Thermometer (VNT200)
Body: 34.0 °C – 43.0 °C (93.2 °F – 109.4 °F)
Object: 0 °C – 100.0 °C (32.0 °F – 212.0 °F)
0.1 °C (0.1 °F)
Body Mode:
±0.2 °C for the range 35.0 °C – 42.0 °C
(±0.4 °F for 95.0 °F – 107.6 °F)
±0.3 °C (±0.5 °F) for the range outside
35.0 °C – 42.0 °C (95.0 °F – 107.6 °F)
Surface Mode:
±2.0 °C for the range 0.0 °C – 100.0 °C
(±3.6 °F for 32.0 °F – 212.0 °F)
Liquid Crystal Display, 4 digits plus special
icons
Normal: Green backlight, One long beep for
normal temperature
Elevated or high temperature: Yellow or Red
backlight, 4 double beeps
Erase memory: one long beep
15 °C – 40 °C (59.0 °F to 104 °F)
Approx. 20 seconds after any button is pressed
85.6 g (with batteries), 63.0 g (w/o batteries)
-25 °C to 55 °C (-13 °F – 131 °F)
15–95% non-condensing
(2) AAA Batteries - at least 1000 measurements
700-1060 hPA (0.7-1.06 atm)