IMPORTANT SAFETY INFORMATION

  • High, prolonged fever requires medical attention especially for young children. Please contact your physician.
  • Do not allow children to take their temperatures unattended.
  • Do not allow children to walk or run during temperature taking.

If you have any questions or comments about the Vicks Digital Thermometer, call our toll-free Consumer Relations Line: 1-800-477-0457 or e-mail consumerrelations@kaz.com.

CHANGING THE DISPLAY FROM FAHRENHEIT (F) OR CENTIGRADE (C)

With the thermometer in the OFF position, hold down the center button until the display shows Lo. Release the button. To choose desired scale, press the button again to move between the "F" or "C" icon shown below the Lo. Once the "C" or "F" starts to blink, push the button again to turn off the thermometer. You can now turn on the thermometer and the display will be in Fahrenheit (F) or Centigrade (C) based on the scale you set in the above steps. Your thermometer will return to Fahrenheit (F) readings when you replace your battery. You can repeat this process to switch to Centigrade (C).

TEMPERATURE READINGS

Temperature readings vary from person to person. Although there is no one "normal" temperature reading, a temperature, taken orally, ranging between 97°F and 100°F is considered normal. A rectal temperature is generally 1° higher and an underarm (axillary) temperature will be 1° lower.

The best method to determine your own normal temperature is to use the thermometer when you are feeling well. Record your reading twice a day (early morning and late afternoon). Take the average of the two temperatures. This is considered your normal body temperature. Any variation from it may indicate some sort of illness and you should consult your physician.

BEFORE USE

Your Vicks Digital Thermometer is a 3-in-1 thermometer for oral, rectal, or underarm use. Whichever method is used, it is recommended that for 15 minutes prior to use, avoid eating or drinking any liquids, exercising, taking showers or baths or smoking.

BEFORE USE


Before first use, remove label from the display.

PROBE COVERS

Disposable probe covers are provided with your Vicks Digital Thermometer. Place a cover on the probe tip each time the thermometer is used to help prevent spread of germs. Additional probe covers can be purchased at most drug stores or pharmacy departments.

OPERATING YOUR Vicks DIGITAL THERMOMETER

  1. TURNING THE UNIT ON
    1. Turn unit on by pressing the On/Off button (Fig. 1).
      OPERATING YOUR Vicks DIGITAL THERMOMETER Fig. 1
    2. Wait for unit to get ready.
      – A beep will sound and the display will perform a self-test for about 2 seconds (Fig. 2).
      OPERATING YOUR Vicks DIGITAL THERMOMETER Fig. 2

      – The display will show last measurement for 2 seconds (Fig. 3).
      OPERATING YOUR Vicks DIGITAL THERMOMETER Fig. 3

      – When the thermometer starts to measure, the display will show "L" if lower than 90 degrees F (Fig. 4).
      OPERATING YOUR Vicks DIGITAL THERMOMETER Fig. 4
  2. SELECTING A TEMPERATURE LOCATION
    • Oral Use
      1. It is suggested to use a probe cover for Oral Use. Discard the probe cover after taking a temperature.
      2. It is important to place the tip of the thermometer well under the tongue to get a good, accurate reading. (Fig. 5) Place sensor tip in areas marked with "". Keep mouth closed and sit still to help ensure an accurate measurement.
        OPERATING YOUR Vicks DIGITAL THERMOMETER Fig. 5
      3. When the peak temperature is reached, 10 beep signals will sound and the "°F" sign will stop flashing.
      4. Turn the thermometer off by pressing the On/Off button. If you forget to turn it off, the thermometer will automatically turn off after approximately 10 minutes.
      5. Dispose of used probe cover and wash the thermometer as recommended.
    • Under-the-arm (Axillary) Use
      This method is used for babies and young children.
      1. Wipe the underarm with a towel.
      2. Place the probe tip under the arm so the tip is touching the skin and position your arm next to your body (Fig. 6). With a young child, it is sometimes helpful to hug the child to keep their arm next to their body. This ensures that the room air does not affect the reading.
        OPERATING YOUR Vicks DIGITAL THERMOMETER Fig. 6
      3. When the peak temperature is reached, 10 beep signals will sound and the "°F" sign will stop flashing. The temperature is now confirmed.
        Note: This method produces a temperature 1° lower than a temperature taken orally.
      4. Turn the thermometer off by pressing the On/Off button. If you forget to turn it off, the thermometer will automatically turn off after approximately 10 minutes.
      5. Wash the thermometer as recommended.
    • Rectal Use
      Commonly used for babies, young children, or when it is difficult to take an oral or underarm temperature.
      1. Cover the thermometer's tip with a probe cover and lubricate with a water-soluble jelly for easier insertion. Do not use a petroleum jelly. Read the label of the lubricant to be sure you are using the right kind.
      2. Lay the patient on his/her side. If the patient is an infant, the proper position for a baby is to lay on its stomach with legs hanging down, either across your knees or at the edge of a bed or changing table. This positions the infant's rectum for safe and easy insertion of the thermometer.
      3. Gently insert the tip of the thermometer NO MORE THAN 1/2 inch into the rectum. If you detect resistance, stop. Hold the thermometer in place during measurement.
      4. When the peak temperature is reached 10 beep signals will sound and the "°F" sign will stop flashing. The temperature is now confirmed.
        Note: This method produces a temperature 1° higher than a temperature taken orally.
      5. Turn the thermometer off by pressing the On/Off button. If you forget to turn it off, the thermometer will automatically turn off after approximately 10 minutes.
      6. Dispose of used probe cover and wash the thermometer as recommended.

FEVER SIGNAL

The Fever Signal feature alerts you of temperature readings above 99.5°F with a flashing display and a rapid alarm tone that lasts for about 10 seconds.

TO RECALL THE LAST TEMPERATURE

When the thermometer is turned on, the display will show a test, after which the last measured temperature will be shown for approximately 2 seconds on the LCD display.

CLEANING INSTRUCTIONS

  • Clean the probe tip by washing with soap and warm water or by disinfecting with rubbing alcohol (70% isopropyl alcohol).
  • Wipe dry with soft cloth.
  • DO NOT BOIL OR CLEAN IN DISHWASHER. This will cause the thermometer to no longer function and will void the warranty.
  • Do not wash the unit with any thinner or chemical solvent.

CHANGING THE BATTERIES

The Vicks® Digital Thermometer features a long life battery. When the "" appears in the lower right of the display, the battery is exhausted and needs replacing.

  1. Unscrew the battery cap with a coin.
  2. Replace the battery with a 1.55V, LR41 alkaline, L736 or SR41 silver oxide type or equivalent. Insert the new battery with the positive (+) side facing the back of the unit.
  3. Replace the cover and screw back into place, making sure that the cap is secure to protect the battery compartment from moisture.

To protect the environment, dispose of empty batteries at appropriate collection sites according to national or local regulations. Keep out of reach of young children, elderly and pets.

SPECIFICATIONS

Battery Life: More than 200 hours of continuous operation.
Temperature Range: 90.0-109.9°F. If less than 90.0°F an "L" is displayed. If more than 109.9°F an "H" is displayed.
"BPA Free" Implies:

  1. Plastics used to make the thermometer are BPA Free
  2. A comprehensive audit to ensure a BPA Free process
  3. A screening test based on acceptance criteria

Beeper: Unit will beep for approximately 10 seconds when peak temperature is reached.
Accuracy in Waterbath: +/-0.2°F between 96.0-107.0°F at room temperature of 71°F.
Type of Thermometer: Predictive

TEST PROTOCOL (Laboratory use only)

Test Protocol for testing to ASTM Standard E1112:

  1. Place thermometer into a stable liquid bath with a temperature set above 95°F. The tip of the thermometer should be approximately 0.8 inches (2cm) below the surface.
  2. Wait for 10 seconds, then turn thermometer on by pressing the blue "On / Off" button.
  3. When the measurement is completed (approximately 15 seconds), record the temperature reading.
  4. Do not touch or hold thermometer when taking a measurement in liquid bath.

1 YEAR LIMITED WARRANTY

You should first read all Instructions before attempting to use this product.

  1. This 1 year limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warrant. KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.
  2. At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship.
  3. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.

Call us toll-free at 1-800-477-0457 or e-mail: consumerrelations@kaz.com. Please be sure to specify a model number.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE PRODUCT OR PERSONAL INJURY.

© 2016 All rights reserved.
Kaz USA, Inc., a Helen of Troy Company
Marlborough, MA 01752

This product is distributed under license from The Procter & Gamble Company.
Vicks and other associated trademarks are owned by The Procter & Gamble Company.
Made and printed in China.

CONSULT INSTRUCTIONS FOR USE

Helen of Troy CREATIVE DEPARTMENT ARTWORK SPECIFICATIONS

Brand: Vicks
Category: Thermometer owners manual
Models: V901USV1
Artwork Part #'s: 31IMV901204R1
Die Line Part #: NA
Oracle Desc.: OWNER'S MANUAL, KAZ Artwork, V901USV1
Subject: Owners Manual
Region: US
Size: IN: W4.75 x H15.5; MM: W NA x H NA
Scale: 100
Material: 70# Uncoated
Page count: 1/1
Revision: 2
Date: 21MAR16
Release Date: 30MAR16
Rerelease Date:

Quality Requirement of Artwork and Quality
Clarification Process of Artwork Printing:
Meet Eng-QS-06&02

Kaz USA, Inc., a Helen of Troy Company
Creative Services
Marlborough, MA 01752, USA
+1 508 490 7000

Videos

How to change a Vicks thermometer from C to F Video

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Vicks Digital Thermometer V901US Manual

Advertisement

Need Assistance?

Do you have a question about the V901US that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents