Canada: CSA C22.2 No 213-M1987 (R2008), CSA C22.2 No 25-1966 (R2004)
IP67

International IEC

IEC 60079-0:2011, IEC 60079-11:2011

Europe

EN 60079-0:2012, EN 60079-11:2012
ATEX Directive
This product conforms with the requirement of ATEX directive. The ATEX Directive 94/9/EC is a
European CE Mark directive concerning products that are designed for use in potentially explosive
environments.
II 3 G D
Ex ic IIC T6 Gc
Ex ic IIIB T88°C Dc
Tamb -20° to 50°C
Where . . .
indicates . . .
Tamb
Ambient Temperature
II
Equipment Group II
3 G
ATEX Category Gas Zone: Equipment Suitable for Zone 2
3 D
ATEX Category Dust Zone: Equipment Suitable for Zone 22
Ex
Explosion Protection
ic
Intrinsic Safety Type of Gas Protection
IIC
Hydrogen/Acetylene Gas Group
T6
85°C Maximum Surface Temperature in Gas Locations
Gc
Equipment Suitable for Gas Zone 2
ic
Intrinsic Safety Type of Dust Protection
IIIB
Non-Conductive Dust Group
T88°C
88°C Maximum Surface Temperature in Dust Locations
Dc
Equipment Suitable for Dust Zone 22