Download Print this page

Mitsubishi Electric EHWT17D-MHEDW Data Book page 8

Water to water heat pump
Hide thumbs Also See for EHWT17D-MHEDW:

Advertisement

2
Specifications
2.4 Water to Water Heat Pump (WTW)
Model name
Dimensions
Height
Width
Depth
Casing
Munsell
RAL code
Material
Product weight (empty)
Product weight (full)
Gross weight
Water volume of heating circuit in the unit *1
Brine/Water volume of ambient loop circuit in the unit
Type of Installation
Electrical data
Heat pump
Power supply
(exclude immersion
heater)
Breaker
Booster heater
Power supply
Capacity
Heater step
Current
Breaker
Immersion heater
Power supply
Capacity
Current
Breaker
Water circulation
Type
pump
Input
Speed 1
(Primary circuit)
(10/20/max L/min)
Speed 2
Speed 3
Speed 4
Speed 5
Performance
Current
Speed 1
curve:
(10/20/max L/min)
Speed 2
please refer
Speed 3
to section 4.6.4
Speed 4
Speed 5
Water circulation
Input
Speed
pump
Speed (Default setting)
(DHW circuit)
Speed
Current
Speed
Speed (Default setting)
Speed
Flow rate
Speed
Speed (Default setting)
Speed
Flow rate
Primary circuit
Max.*2
Min.*3
Ambient loop
Max.*2
Min.*3
Heat exchanger
Ambient loop circuit - Refrigerant
Refrigerant - Primary circuit water
Primary circuit water - Domestic hot water
Domestic hot
Volume
water tank
Material
Declared load profile
Average climate
η
(water heating efficiency)
wh
Water heater energy efficiency class
Expansion vessel
Volume
(Primary circuit)
Charge pressure
Safety device
Primary circuit
Control thermistor
Pressure relief valve
Flow sensor (Min. flow)
BH manual reset thermostat
BH thermal Cut Off
DHW tank
Control thermistor
IH manual reset thermostat
Temperature & pressure
relief valve
Control thermistor
Ambient loop
Flow switch (Min. flow)
Control thermistor (High)
Control thermistor (Low)
Refrigerant circuit
Pressure switch
Pressure sensor
Connections
Water
Primary circuit
DHW circuit
Ambient loop
Refrigerant
Guaranteed
Ambient *4
operating range
Water inlet temperature (Ambient loop)
Min. Water outlet temperature (Ambient loop)
Operating range
Heating
Room temperature
Flow temperature
DHW
Legionella prevention
Sound power level
*1 Volume of sanitary water circuit is not included in this value.
*2 If the water flow rate exceeds maximum, the flow speed will be greater than 1.5 m/s, which could corrode the pipes.
*3 If the water flow is less than the minimum, the flow error will be activated.
*4 The environment must be frost-free.
EHWT17D-MHEDW
mm
1750
mm
595
mm
680
-
6.2PB 9/0.9
-
260 90 05
-
Pre-coated metal
kg
166
kg
345
kg
183
L
5.47
L
3.16
-
Floor standing
Ph
~/N
V
230
Hz
50
A
16
Ph
-
V
-
Hz
-
kW
-
-
-
A
-
A
-
Ph
~/N
V
230
Hz
50
kW
3
A
13
A
16
DC motor
10/13/15
16/21/27
24/32/42
34/46/58
47/58/60
0.2/0.2/0.3
0.2/0.3/0.4
0.3/0.4/0.5
0.4/0.5/0.6
0.5/0.6/0.6
55
69
80
0.25
0.31
0.34
13.5
19.0
22.9
L/min
27.7
L/min
7.1
L/min
24.0
L/min
7.2
-
MWA1-70PA
-
MWA1-44PA
-
CBH18-18H
L
170
Duplex 2010 stainless
-
steel (EN10088)
-
L
-
171
A +
-
L
-
MPa
-
°C
1 to 80
MPa
0.3
L/min
5.0
°C
-
°C
-
°C
40 to 70
°C
85
°C
90
MPa
0.7
°C
10 to 30
L/min
5.5
°C
-20 to 125
°C
-40 to 90
MPa
4.14 ± 0.1
MPa
0 to 5.0
mm
φ28
mm
φ22
mm
φ22
-
R32
°C
0 to 35
%RH
80
°C
10 to 30
°C
4
°C
10 to 30
°C
20 to 60
°C
40 to 60
°C
60 to 70
dB(A)
38
B-23

Advertisement