Other Options; Installing The Dc Input Power Option - Motorola MSF 5000 Instruction Manual

Hide thumbs Also See for MSF 5000:
Table of Contents

Advertisement

Chapter
3
Installation
MSF
5000
Instruction Manual
Other Options
Other Options
The following procedures
are
required to install station options:
DC
input power
option and optional external site frequency standard.
Installing the DC
Input Power Option
The TRN5155 External Battery Cable
Kit
is required
to
install
the
optional
DC
input power
or
battery bank. Perform
the
following
procedures:
1.
Determine the length of black 8-gauge wire required from
the
Junction
Box
to the
negative terminal of
the battery.
2.
Connect
the
black 8-gauge wire from
J605 on the
Junction
Box
to the
negative terminal of
the battery.
NOTE
The TRN5155 External Battery Cable
Kit
contains
10'
of red and
black 8-gauge wire. Runs longer
than
10'
are
not recommended for efficient battery operation.
If
longer runs
are necessary, increase the
wire gauge by
3
AWG
for each increase of
10'
in run length.
Use
the
minimum amount
of
wire
to
make
the
run.
3.
Connect
the
black wire
to the
battery using
the
ring tongue lug (part of kit).
4.
Make
sure
all power
is disconnected from the station.
Refer
to
Chapter
4
-
Alignment
for the proper battery
charge voltage setting before connecting the station
to
the battery.
5.
Connect
P605
into the optional battery power connector (J605) on
the
Junction
Box. Refer to
Figure
3-13 and
Figure
3-14.
6.
Remove
the fuse from the fuse
holder (part of kit).
7.
Mount
the fuse
holder to
the
battery rack,
as
close as possible to the battery
using
the
two
8
X
1-1/4" tapping
screws.
8.
Determine, route, and cut
the red
8-gauge wire required
to
run from P605
to
the fuse
block.
3-22
68P81092E03
3/19/94
Chapter
3
Installation
MSF
5000
Instruction Manual
Other Options
Other Options
The following procedures
are
required to install station options:
DC
input power
option and optional external site frequency standard.
Installing the DC
Input Power Option
The TRN5155 External Battery Cable
Kit
is required
to
install
the
optional
DC
input power
or
battery bank. Perform
the
following
procedures:
1.
Determine the length of black 8-gauge wire required from
the
Junction
Box
to the
negative terminal of
the battery.
2.
Connect
the
black 8-gauge wire from
J605 on the
Junction
Box
to the
negative terminal of
the battery.
NOTE
The TRN5155 External Battery Cable
Kit
contains
10'
of red and
black 8-gauge wire. Runs longer
than
10'
are
not recommended for efficient battery operation.
If
longer runs
are necessary, increase the
wire gauge by
3
AWG
for each increase of
10'
in run length.
Use
the
minimum amount
of
wire
to
make
the
run.
3.
Connect
the
black wire
to the
battery using
the
ring tongue lug (part of kit).
4.
Make
sure
all power
is disconnected from the station.
Refer
to
Chapter
4
-
Alignment
for the proper battery
charge voltage setting before connecting the station
to
the battery.
5.
Connect
P605
into the optional battery power connector (J605) on
the
Junction
Box. Refer to
Figure
3-13 and
Figure
3-14.
6.
Remove
the fuse from the fuse
holder (part of kit).
7.
Mount
the fuse
holder to
the
battery rack,
as
close as possible to the battery
using
the
two
8
X
1-1/4" tapping
screws.
8.
Determine, route, and cut
the red
8-gauge wire required
to
run from P605
to
the fuse
block.
3-22
68P81092E03
3/19/94