How to Install a Single QC-S300/QC-S30 Collator
Installing a Single QC-S300/QC-S30 Collator
CAUTION
• Do not install the QC-S300/QC-S30 on an
unstable floor. The machine may fall over.
The machine frame may be twisted, and this
could affect the machine performance.
• The QC-S300/QC-S30 weighs about 73Kg
(160.6 lb). This machine must be installed
by at least two people.
1.
Unpack the collator.
• This machine must be moved by at least two people.
• Check the accessories.
2.
Install each QC-S300/QC-S30 on the table
by following the steps below.
If optional MT-100 table is used, follow
the steps (1) through (3) described below.
(1) Attach the base plate at the bottom of the QC-
S300/QC-S30 using two mounting screws.
Important
• Attach the base plate in the correct direction referring
to the figure to the right. (Two left feet enter the holes
on the base plate.)
(2) Place the QC-S300/QC-S30 on the MT-100.
• Insert the projection on the base plate into the holes on
MT-100.
(3) Install four skirts.
Important
• Be sure to push the bottom of the transport door side
of the QC-S300/QC-S30 when moving the machine.
Do not push the bin side. This could cause the QC-
S300/QC-S30 to fall over.
CAUTION
• Be sure to turn off the power switch on the
QC-S300/QC-S30.
2
* Choose a stable table which can support at least 73
kg (160.6 lb) to install QC-S300/QC-S30.
1,030 (40.5")
340 (13.3")
Table Height : 600mm (23.7")
* If optional table MT-100 is used, installation space
is mentioned below.
1,030 (40.6")
363 (14.3")
220 (8.7")
84 (3.4")
Table Height : 572mm (22.6")
Mounting
Screw
Left Feet
21101
20102M1
mm(inch)
363 (14.3")
960 (37.8")
138 (5.4")
196 (7.7")
21101
10101E1
mm(inch)
994 (39.2")
196 (7.8")
21101
20102N1
Projection
Base Plate
21101
20101J1
MT-100
Skirt
21101
20101L1