1. Display: 3 1/2 digit LCD (1999)
2. Function switch: A switch that selects
the different function modes or thresholds. To
ensure a long battery life, turn off the device
when not used.
3. "SeLeCT" button: To choose between AC
and DC voltage, or resistance/diode/continuity
modes.
4. "HOLD" button: By pressing this button the
measured result on the screen is held. You can
continue measuring with another press of this
button. This button also starts the device when
it is in standby mode.
5. "
" button: To select the lamp function,
hold this button down for more than 2 seconds.
Do the same for turning it off. If you do not
press the buttons, the lamp will turn off after 15
seconds.
6. measuring pin: The inward measuring
point for measuring voltage, current (<200mA),
resistance, and diode. (positive)
7. measuring cable: Measuring earth
(negative)
t
d
He
isplay
10
9
8 13
11
12
8. Continuity measurement display
9. Diode measurement display
10. Automatic treshold display
11. Direct voltage measurement display
12. Alternate voltage measurement display
anel
3
2
1
14
15
16
17
13. Hold function display
14. Low battery power display
15. Resistance measurement display
16. Current unit display
17. Voltage unit display
U
i
sage
nstrUctions
measuring direct voltage
Set the function switch to the "V"position.
Press the "SELECT" button to switch to
"DC"mode.
Connect the measuring wire and the
measuring pin to the measured voltage.
The display shows the measured value with
the pin's polarity.
Note: Inward impedance: app..: 10mΩ The maximum
measurable voltage is 600V
measuring alternate voltage
Set the function switch to the "V"position.
Press the "SELECT"button to switch to "AC"
mode.
Connect the measuring wire and the
measuring pin to the measured voltage.
The display shows the measured value .
Note: Inward impedance: app.: 10mΩ
Frequency range: 40Hz – 400Hz
max. measurable voltage: 600V
measuring direct current
Set the function switch to "mA" position.
Press the "SELECT" button to switch to
"DC"mode.
Connect the measuring wire and the
measuring pin to the measured current
serially.
The display shows the measured value with
the pin's polarity.
Note: max. measurable current is 200mA, if measuring a
higher current the built-in fuse will melt.
measuring alternate current
Set the function switch to "mA" position.
Press the "SELECT"button to switch to "AC"
mode.
Connect the measuring wire and the
measuring pin to the measured current
serially.
The display shows the measured value.
Note: max. measurable current is 200mA, if measuring a