10. Care should be taken to ensure that all pipework fittings and connections are
secure. This is particularly important on the pump inlet pipework network, due to
the potential for air to be drawn into the system should suction conditions exist.
11. All connection pipework must be adequately and rigidly supported.
12. The flexible hoses supplied are primarily for vibration isolation, and should be
installed straight. They may be bent to a maximum of 30
must be allowed to form a uniform swept curve, and must not be stressed in any
way by the plumbing configuration.
13. The pump motor is air cooled and it is important that the flow of air is not impeded
around the appliance. Damage to fabrics may occur if allowed to foul the motor
air vents - avoid a position in which the product could become frozen.
14. Do not rigidly secure pump unit to the mounting surface.
15. Install inlet and outlet pipework to meet pump flexible hoses, flush through
pipework fully before connecting to pump, and then complete plumbing
installation.
Cistern
DHW
Unsuitable Layout for Mira Enduro Pump
Mixing
Valve
Figure 5
13
o
, in which case they
Pump