HOW TO INSTALL IT COMPONENT
Drill the air outlet hole using a core drill
Using a cutter, scissors or a small saw, cut the two halves of the tube
separately or the whole tube, taking care to respect the length "P"
previously measured.
W3-3HP e W4-4HP
Slightly rotate the tube, so that the 4 "locks" are positioned
at the limit stop of the slot on the counterframe
W3-3HP e W4-4HP
Insert the tube in the hole drilled in the wall
Place the counter-frame on the wall where you wish to install the air-
conditioner and, respecting the minimum distances from the walls
indicated in picture 1, mark carefully the centre of the air outlet hole.
Fig.3
Measure the depth of the wall including the counter-frame as well
(approx. 10 mm).
Fig.5
Insert the 4 "locks" of the tube into the 4 holes on the counter-frame
(the fixing crownings on the counter-frame will have to rest on the
side where the air intake tube protrudes)
Fig.7
Insert the tube fixed on the counter-frame in the hole in the wall.
Fig.9
After placing the counter-frame perfectly straight, mark the 5 holes
for the wall fixing of the counter-frame
Fig.11
W3-3HP e W4-4HP Ø 152 mm
W5-5HP Ø 202 mm
W3-3HP e W4-4HP Ø 150 mm
W5-5HP Ø 200 mm
W3-3HP e W4-4HP
Fig.8
W5 e W5HP
Fig.10
Fig.4
Fig.6
9 di 24