  • Page 1 Double Duct Air Conditioner ITA - ENG INSTALLAZIONE E MANUALE D’USO INSTALLATION AND USER MANUAL MADE IN ITALY...
  • Page 2 SANTIAGO...
  • Page 3 SANTIAGO...
  • Page 4 SANTIAGO...
  • Page 5 Modello SANTIAGO Potenza condizionamento* W (BTU/h) 3480 Potenza riscaldamento* W (BTU/h) 3180 Resistenza elettrica di post riscaldamento* W 2000 Voltaggio (V) Consumo in raffreddamento* (W) Amperaggio in raffreddamento* (A) Consumo in riscaldamento* (W) 790+2000 Amperaggio in riscaldamento* (A) 3.7+8.7 Volume aria (m3/h)
  • Page 6 SANTIAGO...
  • Page 7 SANTIAGO...
  • Page 8 SANTIAGO...
  • Page 9 SANTIAGO...
  • Page 10 SANTIAGO...
  • Page 11 SANTIAGO...
  • Page 12 SANTIAGO...
  • Page 13 SANTIAGO...
  • Page 14 SANTIAGO...
  • Page 15 SANTIAGO...
  • Page 16 SANTIAGO...
  • Page 17 SANTIAGO...
  • Page 18 SANTIAGO...
  • Page 19 Il filtri deve essere regolarmente pulito per mantenerlo efficace. Sfilatelo come dalla fiugra secondo la freccia lavatelo con acqua tiepida senza saponi o detergenti. Solo quando è perfettamente asciutto riponetelo nel suo alloggiamento ATTENZIONE: Non usare il climatizzaotre senza filtro. SANTIAGO...
  • Page 20 FILTRO ELETTROSTATICO PASSIVO ANTIBATTERICO LIFT IT UP HERE LIFT IT UP HERE SANTIAGO...
  • Page 21 Per la pulizia dei filtri, consultare il punto 3.14 MANUTENZIONE “PULIZIA DEI FILTRI” ATTENZIONE: Non coprire il riscaldatore elettrico durante il lavoro. La distanza tra il riscaldatore elettrico e mobili di legno o altri mobili infiammabili deve essere superiore a 1 metro SANTIAGO...
  • Page 22 La temperatura massima di esercizio per l’aria condizionatore: (max raffreddamento: esterno DB43°C / WB26°C, interno DB32°C / WB23°C; riscaldamento min: esterno DB-5°C / WB-6°C, interno DB20°C) SANTIAGO...
  • Page 23 + 7cm per flessibilità di assemblaggio. (FIG.2/FIG.3) Fissate la griglia e posizionate l’unità condizionante nel seguito, la- OSLO 4.0/4.2 sciandovi un po di spazio per poter operare. FIG.2 Il risultato finale sarà il seguente a seconda del tipo di griglia adottata: FIG.3 SANTIAGO...
  • Page 24 SANTIAGO...
  • Page 25 GARANZIA 12 MESI + 12 MESI NELL’AMBITO PRIVATO La società Fintek S.r.l., con sede in Via Tonso di Gualtiero, 46 - 47896 Faetano RS DICHIARA che i seguenti prodotti: La società FINTEK S.r.l., con sede in ViaTonso di Gualtiero 46 47896 Faetano Rep.
  • Page 26: Table Of Contents

    3.6 FAN MODE 3.7 SLEEP MODE 3.8 AUTO MODE 3.9 TIMER OFF FUNCTION 3.10 TIMER ON FUNCTION 3.11 ELECTRICAL HEAT FUNCTION 3.12 ON BOARD CONTROL FUNCTION 3.13 FRESH AIR SYSTEM 3.14 INSTALL AND CHANGE THE BATTERY 3.15 MAINTENANCE 3.16 PROBLEM SOLVING SANTIAGO...
  • Page 27: General Information

    Return the air conditioner to an Should the booklet be damaged or lost, please authorised service center for examination and request an additional. repair to avoid a hazard. SANTIAGO...
  • Page 28: Reciving The Goods

    They must be removed supply with system impedance no more than from the remote control when they reach 0.222 ohm. In case necessary , please the end of their life and disposed of consult your supply authority for system responsibly. impedance information. SANTIAGO...
  • Page 29: Technical Features

    1.GENERAL INFORMATION ENGLISH 1.6 TECHNICAL FEATURES(P1,P2) Model SANTIAGO 3480 Cooling capacity*W 3180 Heating capacity*W 2000 Electrical Heat*W Rated voltage(V) Absorbed power in cooling*( Absorbed current in cooling*( ) Absorbed power in heating*( 790+2000 Absorbed current in heating*( ) 3.7+8.7 Air flow(...
  • Page 30: Installation

    (plants, and their leaves, slats or paneling, drain pipes, overflows and gratings, etc.). Any obstruction could interfere with the correct performances of the air conditioner. Outdoor Indoor SANTIAGO...
  • Page 31 2.INSTALLATION ENGLISH SANTIAGO...
  • Page 32: Drilling The Wall

    Outdoor Hard terminal System “A” is more common use, and the discharge pipe go outside where there is no problem to connect or to discharge it, this solution is OK for hot country and normal cold temperature out side. SANTIAGO...
  • Page 33: Fastening The Bracket

    The manufacturer is not liable in case of underestimation of the structural consistency of the anchorage made at the time of installation. SANTIAGO...
  • Page 34: Fitting The Gratings

    6mm. Tighten the cord and fasten it to the dent on the internal flanges. SANTIAGO...
  • Page 35: Fitting The Air Conditioner On Bracket

    LIFT IT UP Water LIFT IT UP Water cap HERE HERE SANTIAGO...
  • Page 36: Introduction Of Lcd Icons

    CLOCK BUTTON: Adjust the clock LOUVER SWING BUTTON: Adjust the airflow direction SLEEP BUTTON: Automatically adjusting the setting temperature according the circadian rule. RESET BUTTON ELECTRICAL HEAT BUTTON: Switch on the electrical heat in order to get enough heating capacity in cold winter. SANTIAGO...
  • Page 37: Heating Mode

    Press the ON/OFF button " ", switch off the air conditioner. Next time when this button is pressed, the air conditioner will operates in this mode by memory. SANTIAGO...
  • Page 38: Dry Mode

    Room temperature-setting temperature>3℃ middle speed. Room temperature- setting temperature>1℃ low speed. Press the ON/OFF button " ", switch off the air conditioner. Next time when this button is pressed, the air conditioner will operates in this mode by memory. SANTIAGO...
  • Page 39: Sleep Mode

    For auto fan, the speed is chosen by the difference of room temperature and setting temperature. Press the ON/OFF button " ", switch off the air conditioner. Next time when this button is pressed, the air conditioner will operates in this mode by memory. SANTIAGO...
  • Page 40: Timer Off Function

    1 minute. Set up the operation MODE, TEMPERATURE, FAN SPEED etc., when the time is arrived, the air conditioner will start automatically. If the TIMER ON button is pressed again, the TIMER ON setting will be cancelled. SANTIAGO...
  • Page 41: Electrical Heat Function

    LCD, starting the assistant heat; press this button again, stop the assistant heat. Press the ON/OFF button “ ”, switch off the unit. Next time when this button is pressed, the unit will operates in this mode by memory. SANTIAGO...
  • Page 42: On Board Control Function

    The display will show both setting temperature and ambient temperature. After adjusting the setting temperature, the setting temperature will flash 15 minutes on the display, then the display will show the ambient temperature for 70seconds. After that, the display will be off until next adjustment. SANTIAGO...
  • Page 43: Fresh Air System

    - Insert the battery(AAA,2pcs), the positive must be same with the mark on the plastic surface. - Reinstall the cover of battery. Inspection: If press ON / OFF button “ ” no icons are displayed, please install the battery again. SANTIAGO...
  • Page 44: Maintenance

    HERE approaches. With active carbon filter, the room air would be fresh and good for the body health. Is advisable to change them every three month, because it’s not possible to wash or clean them. SANTIAGO...
  • Page 45: Problem Solving

    - Strange smell in the room. Water drips from the air conditioner. - The remote control does not work. - The air conditioner does not work for 3 min when switched on. SANTIAGO...
  • Page 46 été acheté. donde adquirió el producto. onde comprou o produto. SANTIAGO...
  • Page 47 12 MONTH WARRANTY + 12 MONTHS IN THE AREA PRIVATE FINTEK S.r.l., with registered office in ViaTonso di Gualtiero 46 47896 Faetano Rep. Of San Marino DECLARES that the following products: SANTIAGO 1 years are guaranteed from the date of purchase if aimed at professional use 24 months if in the private sphere.
  • Page 48 Don’t miss the video presentations of our air-conditioning units and much more on our YouTube channel via Tonso di Gualtiero, 46 47896 Faetano RSM +378 0549 901 950 commercialeitalia@finteksrl.com www.finteksrl.com WWW.FINTEKSRL.COM...