DS-TDSB00-EKT/4m Fall Detection Radar User Manual...
Page 2
The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (https://www.hikvision.com/).
Page 3
Fall Detection Radar • User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Provides additional information to emphasize or supplement important points of the main text. Indicates a potentially hazardous situation, which if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results.
Remote and non-contact posture detection. Small size, light, and easy installation. Specification Refer to the table below for the device specification. DS-TDSB00-EKT/4m Fall Detection Radar Specification Parameters Values Working Frequency 60 to 64 GHz Modulation Wave FMCW...
Refer to the figures below for the device dimension and appearance overview. Dimension (unit: mm) Appearance Cables Description Refer to the table below for the cables description. DS-TDSB00-EKT/4m Fall Detection Radar Cables Description Color Name Function +12 V 12 VDC...
Install the device on the wall at a height of 2 m. Make sure that the device is centered horizontally in the detection area and there is no obstruction in front of it. Refer to the figures below for the device installation overview. DS-TDSB00-EKT/4m Radar Installation Overview...
Fall Detection Radar • User Manual Chapter 2 Software Instruction Device Connection You can connect the device via Wi-Fi or RS-485. Enter the corresponding information according to the different connection modes. You can connect the radar via Wi-Fi. Before You Start Power on the radar (12 V).
Fall Detection Radar • User Manual IP address: 192.168.4.1. Port No. : 20000. Connection Setting Click Confirm. You can connect the radar via the serial port. Open the IRS60-3 Radar PC tool. Click Connection Settings. Select Serial Port. Select Port.
Fall Detection Radar • User Manual Parameter Settings Click Parameter Settings and click Get after SoftVersion to view the software version. Go to Parameter Settings → Delay Time to set the delay time. If the radar detects the target person fell and stood up within the set delay time, it will not alarm. Otherwise, it will report a falling alarm signal.
Fall Detection Radar • User Manual Detection Boundary Click Parameter Settings to set the radar status. Enter standby mode The radar will be standby and stop emitting electromagnetic waves. If the radar is powered off and does not receive wakeup command after powered on again, then it will still be standby mode.
Page 12
Fall Detection Radar • User Manual Open the IRS60-3 Radar PC tool. Press F1 button on the keyboard. Menu Page Enter IP Address and Radar Port (IP address: 192.168.4.1; radar port: 6666). Click Connect. Click Browse to select the firmware to be upgraded. Select Network Segment as the same network segment with radar and Mode as Auto.
Fall Detection Radar • User Manual Click Confirm. Click Start Update. Upgrade Radar Network Configuration You can set the radar network. Open IRS60-3 Radar PC tool. Press F2 button on the keyboard. Enter IP Address and Port (IP address: 192.168.4.1; port: 6666).
Page 14
Fall Detection Radar • User Manual Network Configuration Click Connect. Set Work Mode as 3. Click Set. Set AP (Router) SSID and AP (Router) PWD. AP (Router) SSID means the router name. AP (Router) PWD means the router password. Set DHCPC as 0. Set IP, Netmask, and gateway.
Page 15
Fall Detection Radar • User Manual AP SSID means the Wi-Fi name. AP PWD means the Wi-Fi password. Set AP Click Set. Set Device ID as an integer (range: 1 to 999999999).
Page 16
Fall Detection Radar • User Manual Set Device Information Set data report type as 0. Set service IP as Hikcentral Pro service IP. Set service PORT as 20000. Set radar debug PORT as 6666. Set radar Passthrough data PORT as 20000. Set report interval as 1000.