Water Supply - Whirlpool LFP580GR Technical & Service Manual

Table of Contents

Advertisement

TROUBLE
b. Water Supply
Water does not
flow when the
power switch is
on
and
start
button is pressed.
Cushion
Filter
Water
is
not
supplied normally.
Note: When removing the flow sheet, reinstate the filter in place correctly.
Water does not stop
INSPECTION
INSPECTION
Does humming
noise come on
from water
Valve?
No
"magic" joint assembly
Check
water
pressure.
Does water stop
when the plug
is removed or
power switch is
OFF?
No
CAUSES
Yes
Something on the filter of
the water valve or
"magic" hose joint..
Poor connect of 6-pin
connectors (blue& white).
Water valve is defective.
Water level sensor is
defective.
Control circuit board is
defective.
Low
High
Something in the air trap
hose or air leaks from a
Yes
part related water level
sensor system.
Water level sensor is
defective.
Control circuit board is
defective.
Something on the
diaphragm on the water
valve.
Diaphragm is deformed
4
LFP580GR
REMEDY
Clean the filter.
Repair or replace.
Replace.
Replace.
Replace.
Remove
the
flow
sheet of the water
valve .
Replace the water
valve.
Clean the filter on the
water valve or "magic"
joint assembly.
Replace
the
water
valve.
Clean or replace.
Replace .
Replace.
Replace or
disassemble the
valve and clean
the diaphragm
Replace

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents