CAUTION
The unit must be transported in an upright position.
If laid on its side, all glass surfaces must be secured
with tape, and water must be drained from the unit.

REVERSIBLE ACCESS DOOR

The Flav-R-Fresh access door may be hinged on either
the left or right side for your convenience. See Figure 6.
To reverse the door hinge, follow these instructions:
1. Remove the top hinge pin screw holding door
to hinge. Remove nylon washer.
2. Tip the door assembly toward you (away from
cabinet) and lift gently to clear the bottom hinge
assembly. Remove nylon washers.
3. Remove the screws holding hinges to the cabinet.
4. Remove screws from non-hinge side of the cabinet
and insert them in the other side, where the hinge
screws were.
5. Mount hinges on the opposite side, using the original
hinge mounting screws. Do not tighten the screws.
6. Carefully rotate the door 180° and re-install
the hinge pin screw that was removed in Step 1.
7. Remove the hinge pin screw on the end that is now
the top.
8. Carefully place the door assembly with the two (2)
nylon washers onto the bottom hinge.
9. Tip/tilt the door assembly towards the cabinet
and align the door top with the hinge. Re-install
the other door hinge pin with one (1) nylon washer.
10. With the door in place, tighten the hinge mounting
screws, making sure the door is level and in place.

STRIKER PLATE REPLACEMENT

1. Carefully remove striker plate from bottom of door
and clean adhesive from the plate and door glass.
2. Position the striker plate on the top of the door,
making sure when the door is closed the striker plate
locates squarely against the magnet and mark the
position.
3. Clean glass with a non-oily cleaner, such
as isopropyl alcohol (rubbing alcohol),
and do not touch the surface.
4. Attach the striker plate to the glass door at the
marked position using a N.S.F. approved silicon type
adhesive. Let the adhesive dry before closing
the door against the magnet.
Striker Plate
Figure 6. Reversible Access Door

LOCATION

Locate the Display Cabinet at the proper counter
height, in an area that is convenient for use.
The location should be level to prevent the cabinet
or its contents from accidentally falling.
For safe and proper operation, the Display Cabinet
must be located a reasonable distance from
combustible walls and materials. If safe distances
are not maintained, discoloration or combustion
could occur.
The unit must be transported in an upright position.
If laid on its side, all glass surfaces must be secured
with tape, and water must be drained from the unit.
Unit is not weatherproof. For safe and proper
operation locate the unit indoors where the ambient
air temperature is a minimum of 70°F (21°C).
5
INSTALLATION
CAUTION
WARNING
CAUTION
CAUTION
Form No. FDWM-0602

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents