AZIMUTH SYSTEM CONFIGURATION CONTINUED...
CCW ELECTRICAL LIMIT –.174°
CCW PHYSICAL LIMIT –.177°
EAST
CW PHYSICAL LIMIT 125°
CW ELECTRICAL LIMIT 120°
EAST
CW ELECTRICAL LIMIT –.183°
CW PHYSICAL LIMIT –.186°
WEST
VIEWED FROM THE TOP
OF THE SYSTEM
LOOKING DOWN
CCW PHYSICAL LIMIT 235°
CCW ELECTRICAL LIMIT 240°
WEST
VIEWED FROM THE TOP
OF THE SYSTEM
LOOKING DOWN
AZIMUTH AXIS OPTION #3
Characteristics
Spectrum of use: + 360°
Over travel amount: 12°
SU Designation: Azimuth (N-Center)
OVERVIEW:
This azimuth configuration may be used when
360° of travel is necessary with primarily a
northern exposure and avoids limits where most
of the operations are being preformed. Note the
position of the Physical limit switches, they are
on the outside of the electrical limits. Ultimately,
this provides safety when and if a control box
fails.
AZIMUTH AXIS OPTION #4
Characteristics
Spectrum of use: + 240°
Over travel amount: 10°
SU Designation: Azimuth (N-Center)
OVERVIEW:
This azimuth configuration may be used when
240° of travel is necessary with primarily a
northern exposure and avoids limits where most
of the operations are being preformed. Note the
position of the Physical limit switches, they are
on the outside of the electrical limits. Ultimately,
this provides safety when and if a control box
fails.