WATER ELECTROLYZER ROX-30SA-EW ROX-60SA-EW INSTRUCTION MANUAL FOR END USER 3-16 Minamiyakata, Sakae, Toyoake, Aichi 470-1194 Japan L1X007115 (032017)
IMPORTANT SAFETY INFORMATION Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit. WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
Page 3
2. CONSTRUCTION In the context of this manual, the term "sanitizing water" refers to acidic water and "cleaning water" refers to alkaline water. [a] EXTERIOR 1. PRINCIPLE OF ELECTROLYSIS Flow of electrons DC Power Supply Sodium Hydroxide Hypochlorous Acid (HOCl) (NaOH) Electrolytic Cell Positive ions drawn...
Dilutes salt to make salt water. goes off. [5] Neutralizer Neutralizes sanitizing water pH. [d] CONTROL PANEL (A) (B) [ROX-30SA-EW: Control panel (A) only] [6] Neutralizer inlet Open to add in neutralizing agent. [7] Door Open/close to evacuate the salt water pump and add in neutralizing agent.
Page 5
Locate the shut-off valve, water supply valve and drain valve in your site. Note: Ask an authorized Hoshizaki service company for installation of the above options. 4) Open the salt chute door to check the salt level in the salt water tank.
IMPORTANT To use other than the optional dispensing valve, consult an 1. Do not damage the stainless steel surfaces. Use of a authorized Hoshizaki service company. steal brush or steel wool may break oxide film to develop corrosion inside. Refer to the instruction manual provided with the optional dispensing valve.
Page 7
The attachment plug is plugged Plug into a separate receptacle. If the replace cell lamp is flashing, contact an authorized Hoshizaki into a single receptacle with other service company. equipment. The unit shares a single power Use a separate power supply.
3) Press and hold the display select button on the control panels (A) available PURGING SALT WATER PUMP". and (B) [ROX-30SA-EW: control panel (A) only]. The salt water Add neutralizer Add neutralizing agent. See "3. [b] pump starts running and pumping up salt water to purge the salt lamp (red) is NEUTRALIZING AGENT LEVEL".
13. SPECIFICATIONS Model ROX-30SA-EW Electrolysis System Membrane technology Electrolyte Salt containing at least 99% sodium chloride Power Supply 1 phase 220 - 240V 50/60Hz Electric Consumption 250W Pump operation: 550/670W Performance Sanitizing water: pH3 or less, available (Standard) chlorine 20 - 60mg/kg...
14. INSPECTION SHEET Make copies of this page. [a] DAILY INSPECTION SHEET Date Time Sanitizing water Cleaning water Neutralizer Available chlorine concentration* Salt level Neutralizing agent level Water hardness Water leaks around unit Water leaks from water circuit Cell run time Checked by * Sanitizing water only Date...